Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Removal of chromium (VI) from aqueous solutions using surface modified composite nanofibers
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik. Cairo University, Egypt.ORCID-id: 0000-0002-1439-8617
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Biomedicinsk fysik och röntgenfysik.
Vise andre og tillknytning
2017 (engelsk)Inngår i: Journal of Colloid and Interface Science, ISSN 0021-9797, E-ISSN 1095-7103, Vol. 505, s. 682-691Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A novel material composite nanofibers (PAN-CNT/TiO2-NH2) based on adsorption of Cr(VI) ions, was applied. Polyacrylonitrile (PAN) and carbon nanotube (CNTs)/titanium dioxide nanoparticles (TiO2) functionalized with amine groups (TiO2-NH2) composite nanofibers have been fabricated by electrospinning. The nanostructures and the formation process mechanism of the obtained PAN-CNT/TiO2-NH2 composite nanofibers are investigated using FTIR, XRD, XPS, SEM, and TEM. The composite nanofibers were used as a novel adsorbent for removing toxic chromium Cr(VI) in aqueous solution. The kinetic study, adsorption isotherm, pH effect, initial concentration, and thermodynamic study were investigated in batch experiments. The composite nanofibers had a positive effect on the absorption of Cr(VI) ions under neutral and acidic conditions, and the saturated adsorption reached the highest when pH was 2. The adsorption equilibrium reached within 30 and 180 min with an initial solution concentration increasing from 10 to 300 mg/L, and the process can be better described using nonlinear pseudo first than nonlinear pseudo second order model and Intra-particle diffusion. Isotherm data fitted well using linear and nonlinear Langmuir, Freundlich, Redlich-Peterson, and Temkin isotherm adsorption model. Thermodynamic study showed that the adsorption process is exothermic. The adsorption capacity can remain up to 80% after 5 times usage, which show good durability performance. The adsorption mechanism was also studied by UV-vis and XPS.

sted, utgiver, år, opplag, sider
Academic Press, 2017. Vol. 505, s. 682-691
Emneord [en]
Adsorption, Chromium (VI) removal, Kinetics isotherm, Electrospinning, Composite nanofibers
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-215349DOI: 10.1016/j.jcis.2017.06.066ISI: 000410464100073PubMedID: 28654883Scopus ID: 2-s2.0-85021190020OAI: oai:DiVA.org:kth-215349DiVA, id: diva2:1148211
Merknad

QC 20171010

Tilgjengelig fra: 2017-10-10 Laget: 2017-10-10 Sist oppdatert: 2017-10-10bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Søk i DiVA

Av forfatter/redaktør
Mohamed, AlaaToprak, MuhammetMuhammed, MamounUheida, Abdusalam
Av organisasjonen
I samme tidsskrift
Journal of Colloid and Interface Science

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 97 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf