Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Simulation of partially coherent image formation in a compact soft x-ray microscope
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Biomedicinsk fysik och röntgenfysik.
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Biomedicinsk fysik och röntgenfysik.
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Biomedicinsk fysik och röntgenfysik.ORCID-id: 0000-0002-4394-0591
2007 (engelsk)Inngår i: Ultramicroscopy, ISSN 0304-3991, E-ISSN 1879-2723, Vol. 107, nr 8, s. 604-609Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In this paper, we describe a numerical method of simulating two-dimensional images in a compact soft X-ray microscope using partially coherent illumination considerations. The work was motivated by recent test object images obtained by the latest generation inhouse compact soft X-ray microscope, which showed diffraction-like artifacts not observed previously. The numerical model approximates the condenser zone plate as a secondary incoherent source represented by individually coherent but mutually incoherent source points, each giving rise to a separate image. A final image is obtained by adding up all the individual source point contributions. The results are compared with the microscope images and show qualitative agreement, indicating that the observed effects are caused by partially coherent illumination.

sted, utgiver, år, opplag, sider
2007. Vol. 107, nr 8, s. 604-609
Emneord [en]
Image formation; Partial coherence; X-ray microscopy; Zone plates; Computer simulation; Light sources; Mathematical models; X ray diffraction; X ray microscopes; Incoherent sources; Partial coherence; X ray microscopy; Zone plates; Image processing; article; diffraction; illumination; image analysis; mathematical model; microscopy; qualitative analysis; separation technique; simulation; X ray analysis
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-7020DOI: 10.1016/j.ultramic.2006.12.001ISI: 000246937000006Scopus ID: 2-s2.0-34247139671OAI: oai:DiVA.org:kth-7020DiVA, id: diva2:11895
Merknad
QC 20100820. Uppdaterad från In press till Published 20100820.Tilgjengelig fra: 2007-04-20 Laget: 2007-04-20 Sist oppdatert: 2017-12-14bibliografisk kontrollert
Inngår i avhandling
1. Compact Soft X-Ray Microscopy: Sources, Optics and Instrumentation
Åpne denne publikasjonen i ny fane eller vindu >>Compact Soft X-Ray Microscopy: Sources, Optics and Instrumentation
2007 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

This thesis describes the development of a sub-60-nm full-period resolution compact soft x-ray microscope operating in the water-window region (2.3-4.4 nm). Soft x-ray water-window microscopy is a powerful technique for high-resolution imaging of organic materials exploiting the natural contrast mechanism between carbon and oxygen, cf. Sect. 4.1. The thesis discusses the components of, as well as the integration of the microscope, including liquid-jet laser-plasma x-ray sources, optics, simulations, and image-processing tools.

Liquid-jet-target laser-plasma sources for generation of soft x-rays and extreme-ultraviolet radiation are compact sources with high brightness. The work focused on improved target stability, decreased debris, and accurate source characterization. For x ray microscopy applications a liquid-jet target delivery system allowing cryogenic liquids was developed. Source characterization was performed for two different liquid-jet targets: Methanol and liquid nitrogen. For extreme-ultraviolet lithography applications, the potential use of a liquid-tin-jet laser-plasma source was explored including conversion efficiency and debris measurements.

High quality optics are essential in the development of compact x-ray microscopes. For soft x-ray wavelengths, zone plates and multilayer mirrors are used to focus or redirect radiation. This thesis describes the development and characterization of a condenser zone plate suitable for use in a compact soft x-ray microscope operating at λ = 2.478 nm. It also investigates the possibility to perform differential interference contrast microscopy in the water window using a single diffractive optical element. An arrangement for rapid and accurate determination of absolute and local diffraction efficiency of soft x-ray zone plates using a compact laser-plasma source has been developed. The instrument is used to characterize the zone plates fabricated at the Biomedical & X-Ray Physics division at KTH. Through a collaboration with the Fraunhofer-Institut in Jena, Germany, a large diameter spherical Cr/Sc multilayer mirror, suitable as condenser in the compact x-ray microscope, was developed and characterized. The mirror is designed for λ = 3.374 nm and shows a high, and uniform reflectivity of 3%. This increases the photon flux by an order of magnitude compared to the W/B4C mirrors previously used.

The thesis describes the development of a compact soft x-ray microscope with sub-60-nm full-period resolution. It can operate at two different wavelengths in the water window using the soft x-ray laser-plasma sources combined with the condenser optics described above. Imaging is performed by zone plate objectives. The microscope is capable of imaging hydrated biological samples with thicknesses up to ~10 μm. Improvements made to the mechanical design has turned it into a user friendly instrument allowing daily operation. A numerical method was developed to study the effects of partially coherent illumination on 2D imaging. To stimulate experiments on functional imaging in x-ray microscopy an image-analysis algorithm for identifying colloidal-gold particles was developed. Size selective identification and localization of single gold particles down to a diameter of 50 nm was demonstrated.

sted, utgiver, år, opplag, sider
Stockholm: KTH, 2007. s. x, 59
Serie
Trita-FYS, ISSN 0280-316X ; 2007:25
Emneord
soft x-ray microscopy, water window, compact, laser plasma, liquid jet, zone plate optics
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-4342 (URN)978-91-7178-613-5 (ISBN)
Disputas
2007-05-04, FD 5, Albanova, Roslagstullsbacken 21, Stockholm, 13:00
Opponent
Veileder
Merknad
QC 20100819Tilgjengelig fra: 2007-04-20 Laget: 2007-04-20 Sist oppdatert: 2010-08-20bibliografisk kontrollert
2. Phase-Contrast and High-Resolution Optics for X-Ray Microscopy
Åpne denne publikasjonen i ny fane eller vindu >>Phase-Contrast and High-Resolution Optics for X-Ray Microscopy
2010 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

X-ray microscopy is a well-established technique for nanoscale imaging. Zone plates are used as microscope objectives and provide high resolution, approaching 10 nm, currently limited by fabrication issues. This Thesis presents zone plate optics that achieve either high resolution or phase contrast in x-ray microscopy. The high-resolution optics use high orders of the zone plate, which alleviates the demands on fabrication, and the phase-contrast optics are single-element diffractive optical elements that produce contrast by Zernike or differential-interference contrast methods. The advantage of phase contrast in x-ray microscopy is shorter exposure times, and is crucial in the hard x-ray regime. Microscopy in the absorption‑contrast region of the water-window (2.34 - 4.37 nm) also benefits from these optics. The development of the optics for a laboratory soft x-ray microscope spans from theoretical and numerical analysis of coherence and stray light to experimental implementation and testing. The laboratory microscope uses laser-produced plasma-sources in the water-window and is unique in its design and performance. It will be shown that the laboratory microscope in its current form is a user-oriented and stable instrument, and has been used in a number of applications. The implementation of a cryogenic sample stage for tomographic imaging of biological samples in their natural environment has enabled applications in biology, and 3D x-ray microscopy of cells was performed for the first time with a laboratory instrument.

 

sted, utgiver, år, opplag, sider
Stockholm: KTH, 2010. s. x, 61
Serie
Trita-FYS, ISSN 0280-316X ; 72
Emneord
Microscopy, X-ray optics, X-ray microscopy, Soft X-ray physics
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-26781 (URN)978-91-7415-834-2 (ISBN)
Disputas
2010-12-17, FD5, Roslagstullsbacken 21, Stockholm, 15:42 (engelsk)
Opponent
Veileder
Merknad
QC 20101130Tilgjengelig fra: 2010-11-30 Laget: 2010-11-26 Sist oppdatert: 2010-11-30bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopusUltramicroscopy

Personposter BETA

Voght, Ulrich

Søk i DiVA

Av forfatter/redaktør
von Hofsten, OlovTakman, PerVoght, Ulrich
Av organisasjonen
I samme tidsskrift
Ultramicroscopy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 690 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf