Optisk metod för glukosmätning: En studie för framtida icke-invasiva blodglukosmätningar
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Medicinteknik och hälsosystem.
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Medicinteknik och hälsosystem.
2017 (svensk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgaveAlternativ tittel
Optical Method for Glucose Monitoring : A Study for Future Noninvasive Blood Glucose Monitoring (engelsk)
Abstract [sv]

Idag lever cirka 365 000 personer med diabetes i Sverige. Mätningen av blodsocker kan upplevas som besvärlig och smärtsam med den apparatur som idag finns på marknaden. Vidare måste sjukvårdspersonal vara försiktiga vid hanteringen av teststickor pga. av den smittorisk som finns i kontakten med blod. Därför krävs en icke-invasiv mätmetod av blodglukos för att underlätta för diabetiker, eliminera risker för vårdpersonal och ge en möjlighet åt friska personer att ha koll på sitt blodglukosvärde på ett enkelt sätt.Följande examensarbete presenterar sjukdomen, dess följdsjukdomar och problematiken kring blodglukosmätningen. Arbetet har sin grund i en tidigare studie som gjorts kring optisk mätning av glukos, där resultatet visade på att glukos har en ljusabsorberande förmåga. Det påvisades genom att belysa en blandning av natriumkloridlösning och glukos, med infrarött ljus från en lysdiod. Det ljus som transmitterades bearbetades av en krets som bland annat bestod av en fotodetektor. Fotodetektorn genererade vidare en ström som i sin tur gjordes om till en utspänning som förstärktes.Under det arbete som redovisas i denna rapport testas en modifiering av kretsen för att undersöka om det går att upprätta, en korrelation mellan glukoskoncentrationen och utspänningen med hjälp av en transimpedansförstärkare kring fotodetektorn.De uppmätta spänningsvärdena redovisas i grafer och resultatet ger slutsatsen att kretsen ger en bättre korrelation mellan utspänning och glukoskoncentration, men en otillräcklig sådan vilket gör att tekniken inte kan användas kliniskt.

Abstract [en]

Today there are currently living around 365 000 people with diabetes in Sweden. Measuring of blood sugar can be experienced as painful and difficult with blood glucose monitoring devices found in the market. Using lancets and test strip makes direct contact with blood which increases the risk of infection. To reduce these risks and difficulties a non-invasive method is required. This method can even provide an opportunity for healthy individuals to monitor their blood glucose and prevent the disease.This thesis presents the disease, sequelae and the problem around blood glucose monitoring. The work is based on an earlier study about optic measurement of glucose. By illumine a solution of saline and glucose, with infrared-light from a LED, absorption is carried out by the glucose. The amount of transmitted light is detected and processed by a photodetector which generates a current that is converted to a voltage and amplified. This report examines a modification of the circuit used in the previous study to establish a correlation between the glucose concentration and the output voltage by adding a transimpedance amplifier around the photodetector.The results corroborate that the modification with the transimpedance gives a better correlation between the measured output voltage and glucose concentration. The measurements were compiled and plotted to compare which circuit gave a better correlation between the measured output voltage and glucose concentration. The study showed that the modification with transimpedance amplifier gives a better correlation, though it is not enough for clinical use.

sted, utgiver, år, opplag, sider
2017. , s. 22
Serie
TRITA-CBH-GRU ; 2018:113
Emneord [sv]
Glukos, optisk mätning
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-235228OAI: oai:DiVA.org:kth-235228DiVA, id: diva2:1249266
Eksternt samarbeid
EKT på Kungliga Tekniska Högskolan
Fag / kurs
Medical Engineering
Utdanningsprogram
Master of Science in Engineering - Medical Engineering
Veileder
Examiner
Tilgjengelig fra: 2018-09-24 Laget: 2018-09-18 Sist oppdatert: 2022-06-26bibliografisk kontrollert

Open Access i DiVA

Optisk metod för glukosmätning(1158 kB)1245 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1158 kBChecksum SHA-512
94238082ee52dcd3a4a12d6b9f860b7d1b67e51e5f7b9350b5a60da3e17ce8835f592be448a6c81d90308cddfadbe8ae83a76719ad2b9e4dc65d82a83387566a
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 1246 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1372 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf