Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Critical considerations on load-to-failure test for monolithic zirconia molar crowns
Tohoku Univ, Dept Adv Free Rad Sci, Grad Sch Dent, Aoba Ku, 4-1 Seiryo Machi, Sendai, Miyagi 9808575, Japan..
Sweden Dent Sendai, Miyagino Ku, 1-6-2 Tsutsujigaoka, Sendai, Miyagi 9830852, Japan..
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Fiber- och polymerteknologi, Polymera material.
Tohoku Univ, Dept Adv Free Rad Sci, Grad Sch Dent, Aoba Ku, 4-1 Seiryo Machi, Sendai, Miyagi 9808575, Japan..
Vise andre og tillknytning
2018 (engelsk)Inngår i: Journal of The Mechanical Behavior of Biomedical Materials, ISSN 1751-6161, E-ISSN 1878-0180, Vol. 87, s. 180-189Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Application of monolithic zirconia crowns (MZCs) with reduced thickness to the molar region has been proposed, but potential complications have yet to be fully evaluated in laboratory tests. The present study aimed to develop a clinically relevant load-to-failure test in combination with fatigue treatments involving thermal and mechanical cycling (TC and MC) to evaluate the fracture resistance of molar MZCs. MZCs with a minimal thickness of 0.5 mm were bonded to dies made of resin-based composite (RBC), epoxy resin (EP), or polyoxymethylene-copolymer (POM-C). The samples were either untreated (UT) or subjected to TC (5-55 degrees C for 1 x 10(5) cycles) and MC (300 N for 2.4 x 10(6) cycles). The stress generated by TC and MC was simulated by finite element modeling. The load-to-failure test was performed using an inverse V-shaped two-plane indenter and was followed by fractographic analysis. The median values of fracture load for MZC/RBC and MZC/EP in the TC group were significantly lower than those in the UT group. MC also decreased the median value of fracture load for MZC/RBC significantly, but not that for MZC/EP and MZC/POM-C. Fractography revealed that the fracture started in the cervical area in all groups, which is similar to clinically failed crowns. The simulation confirmed stress concentration at the cervical area in both TC and MC groups. The present study suggests that the load-to-failure test using a two-plane indenter could induce clinically relevant fracture of MZCs, the vulnerability of the MZCs depends largely on the die material employed, and MZCs are more likely to be damaged by thermal fatigue than mechanical fatigue.

sted, utgiver, år, opplag, sider
Elsevier, 2018. Vol. 87, s. 180-189
Emneord [en]
Monolithic zirconia crowns, Fractography, Fracture resistance, Thermal fatigue, Mechanical fatigue, CAD/CAM, Finite element modeling
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-237088DOI: 10.1016/j.jmbbm.2018.07.034ISI: 000446286000021PubMedID: 30077077Scopus ID: 2-s2.0-85050811130OAI: oai:DiVA.org:kth-237088DiVA, id: diva2:1258280
Merknad

QC 20181024

Tilgjengelig fra: 2018-10-24 Laget: 2018-10-24 Sist oppdatert: 2018-10-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Personposter BETA

Nilsson, Fritjof

Søk i DiVA

Av forfatter/redaktør
Nilsson, FritjofNiwano, Yoshimi
Av organisasjonen
I samme tidsskrift
Journal of The Mechanical Behavior of Biomedical Materials

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 177 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf