Performance of a passive cooling system for spent fuel pool using two-phase thermosiphon evaluated by RELAP5/MELCOR coupling analysis
KTH, Skolan för teknikvetenskap (SCI), Fysik, Kärnkraftssäkerhet.ORCID-id: 0000-0002-1179-2256
KTH, Skolan för teknikvetenskap (SCI), Fysik, Kärnkraftssäkerhet.
2019 (engelsk)Inngår i: Annals of Nuclear Energy, ISSN 0306-4549, E-ISSN 1873-2100, Vol. 128, s. 330-340Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In the aftermath of the Fukushima Daiichi nuclear accident, a great concern has been raised about enhancing the inherent safety of a spent fuel pool (SFP). A passive cooling system using two-phase thermosiphon loops was concerned in this paper. A RELAP5/MELCOR coupling interface was developed, aiming at simultaneously simulating the transient behaviors of the SFP (by MELCOR) and the passive cooling system (by RELAP5). First the RELAP5 model of the thermosiphon loop was qualified against an experiment of a prototypical scale. Comparisons between the experiment and predictions show a good agreement. MELCOR standalone calculations for both station blackout (SBO) and loss of coolant accident (LOCA) without the passive cooling system demonstrate severe degradation of fuel rods. In contrast, for the SBO accident, the coupling simulation shows that the passive cooling system can effectively remove the decay heat, thus keeping fuel rods intact. As for the LOCA scenario, it is more challenging for the passive cooling system due to: (i) the heat transfer power is low during the drainage of water since the natural circulation of steam is blocked by the residual water at the bottom, leading to unavoidable heat-up and oxidation of fuel cladding; (ii) the heat transfer coefficient between steam and the evaporator is very small, which consequently may require a larger heat transfer surface area. Nevertheless, the heat transfer power substantially increases after the pool is emptied and natural circulation is established. The decay heat can be removed by steam convection, thus maintaining the mechanical integrity of fuel rods and stabilizing the fuel temperature eventually. It is also observed that H 2 production is undesirably promoted because the steam supply is enhanced. However such adverse effect can be diminished by increasing the thermosiphon loops number.

sted, utgiver, år, opplag, sider
Elsevier, 2019. Vol. 128, s. 330-340
Emneord [en]
Coupling analysis, Severe accident, Spent fuel pool, Thermosiphon
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-246416DOI: 10.1016/j.anucene.2019.01.024ISI: 000465054700035Scopus ID: 2-s2.0-85060329248OAI: oai:DiVA.org:kth-246416DiVA, id: diva2:1300752
Merknad

QC 20190329

Tilgjengelig fra: 2019-03-29 Laget: 2019-03-29 Sist oppdatert: 2019-05-14bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Huang, ZhengMa, Weimin

Søk i DiVA

Av forfatter/redaktør
Huang, ZhengMa, Weimin
Av organisasjonen
I samme tidsskrift
Annals of Nuclear Energy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 84 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf