Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Requirements for functional testing of HVDC protection IEDs
ELECTA, KU Leuven, Belgium and EnergyVille, Genk, Belgium.
KTH, Skolan för elektroteknik och datavetenskap (EECS), Elkraftteknik.ORCID-id: 0000-0002-0579-2639
ELECTA, KU Leuven, Belgium and EnergyVille, Genk, Belgium.
ELECTA, KU Leuven, Belgium and EnergyVille, Genk, Belgium.ORCID-id: 0000-0002-7230-6784
Vise andre og tillknytning
2019 (engelsk)Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Development of Intelligent Electronic Devices (IED) for HVDC protection is underway, driven in part by the prospective demands of future multiterminal HVDC systems. There is, however, no consensus on how to test the functionality of an HVDC protection IED. Successful operation of a future multivendor HVDC protection system requires functional specifications and harmonised test procedures for protection system components, including the protection IED. This paper presents an introduction to functional testing methods for HVDC protection IEDs. Evaluating the protection algorithm characteristic using synthetic waveforms is first performed, i.e. ’functional type testing’. Given that test procedures are in part dependent on the protection algorithm, tests are developed and presented for several algorithms. The behaviour of the IED in a power system simulation is then examined during generalised yet representative fault transients, i.e. equivalent to ’dynamic validation type testing’ of AC protection algorithms. The combination of functional and dynamic validation type testing allows the generalised functionality of the IED to be evaluated - testing the algorithm, hardware and software implementation, and overall performance. To provide examples of test procedures, an open-source HVDC IED prototype is tested in a hardware-in-the-loop configuration using a real-time simulator. The operation and accuracy of the protection characteristics are first examined, before the IED performance under representative waveforms is determined. Through tests of several non-unit line protection algorithms, it is shown that, depending on the algorithm applied, the IED is dependable for simulated faults within the protection zone, and secure during external faults. Moreover,the test configurations and procedures required to evaluate the functionality and the criteria for success are developed.

sted, utgiver, år, opplag, sider
2019.
Emneord [en]
HVDC protection, Functional type testing, Dynamic validation type testing, Real-time simulation, HVDC relaying, HVDC protection IED, Hardware in the loop, Standardisation, Harmonisation.
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-260572OAI: oai:DiVA.org:kth-260572DiVA, id: diva2:1355994
Konferanse
CIGRE B4 International Colloquium 1st - 4th October 2019 Johannesburg, South Africa
Merknad

QCR 20191015

Tilgjengelig fra: 2019-09-30 Laget: 2019-09-30 Sist oppdatert: 2019-10-18bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Conference webpage

Personposter BETA

Jahn, IlkaNorrga, Staffan

Søk i DiVA

Av forfatter/redaktør
Jahn, IlkaLeterme, WillemWang, MianNorrga, Staffan
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 139 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf