Analysis of O-Ring Seal Failure under Static Conditions and Determination of End-of-Lifetime Criterion
Bundesanstalt Mat Forsch & Prufung, D-12200 Berlin, Germany..
Bundesanstalt Mat Forsch & Prufung, D-12200 Berlin, Germany..ORCID-id: 0000-0001-5079-2307
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Fiber- och polymerteknologi.ORCID-id: 0000-0003-3049-7225
Bundesanstalt Mat Forsch & Prufung, D-12200 Berlin, Germany..
Vise andre og tillknytning
2019 (engelsk)Inngår i: Polymers, E-ISSN 2073-4360, Vol. 11, nr 8, artikkel-id 1251Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Determining a suitable and reliable end-of-lifetime criterion for O-ring seals is an important issue for long-term seal applications. Therefore, seal failure of ethylene propylene diene rubber (EPDM) and hydrogenated nitrile butadiene rubber (HNBR) O-rings aged in the compressed state at 125 degrees C and at 150 degrees C for up to 1.5 years was analyzed and investigated under static conditions, using both non-lubricated and lubricated seals. Changes of the material properties were analyzed with dynamic-mechanical analysis and permeability experiments. Indenter modulus measurements were used to investigate DLO effects. It became clear that O-rings can remain leak-tight under static conditions even when material properties have already degraded considerably, especially when adhesion effects are encountered. As a feasible and reliable end-of-lifetime criterion for O-ring seals under static conditions should include a safety margin for slight dimensional changes, a modified leakage test involving a small and rapid partial decompression of the seal was introduced that enabled determining a more realistic but still conservative end-of-lifetime criterion for an EPDM seal.

sted, utgiver, år, opplag, sider
MDPI , 2019. Vol. 11, nr 8, artikkel-id 1251
Emneord [en]
EPDM, HNBR, seal failure, leak-tightness, DLO, oxygen permeability, DMA, indenter modulus
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-261040DOI: 10.3390/polym11081251ISI: 000484552900021PubMedID: 31362423Scopus ID: 2-s2.0-85073909707OAI: oai:DiVA.org:kth-261040DiVA, id: diva2:1356703
Merknad

QC 20191002

Tilgjengelig fra: 2019-10-02 Laget: 2019-10-02 Sist oppdatert: 2024-01-17bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Pourmand, PayamHedenqvist, Mikael S.

Søk i DiVA

Av forfatter/redaktør
Jaunich, MatthiasPourmand, PayamHedenqvist, Mikael S.
Av organisasjonen
I samme tidsskrift
Polymers

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 194 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf