An efficient pre-object collimator based on an x-ray lens
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk avbildning. (Medical Imaging)
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk avbildning. (Medical Imaging)
KTH, Skolan för teknikvetenskap (SCI), Fysik.
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk avbildning. (Medical Imaging)ORCID-id: 0000-0002-7725-0548
Visa övriga samt affilieringar
2009 (Engelska)Ingår i: Medical physics (Lancaster), ISSN 0094-2405, Vol. 36, nr 2, s. 626-633Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A multiprism lens (MPL) is a refractive x-ray lens with one-dimensional focusing properties. If used as a pre-object collimator in a scanning system for medical x-ray imaging, it reduces the divergence of the radiation and improves on photon economy compared to a slit collimator. Potential advantages include shorter acquisition times, a reduced tube loading, or improved resolution. We present the first images acquired with a MPL in a prototype for a scanning mammography system. The lens showed a gain of flux of 1.32 compared to a slit collimator at equal resolution, or a gain in resolution of 1.31–1.44 at equal flux. We expect the gain of flux in a clinical setup with an optimized MPL and a custom-made absorption filter to reach 1.67, or 1.45–1.54 gain in resolution.

Ort, förlag, år, upplaga, sidor
2009. Vol. 36, nr 2, s. 626-633
Nyckelord [en]
x-ray imaging, mammography, x-ray optics, multiprism lens, collimation, x-ray flux, acquisition time, resolution
Nationell ämneskategori
Övrig annan teknik Atom- och molekylfysik och optik Radiologi och bildbehandling Medicinsk laboratorie- och mätteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-11634DOI: 10.1118/1.3062926ISI: 000262852600037PubMedID: 19292003Scopus ID: 2-s2.0-59249085647OAI: oai:DiVA.org:kth-11634DiVA, id: diva2:278565
Anmärkning
QC 20100713Tillgänglig från: 2009-11-27 Skapad: 2009-11-27 Senast uppdaterad: 2020-03-09Bibliografiskt granskad
Ingår i avhandling
1. Spectral Mammography with X-Ray Optics and a Photon-Counting Detector
Öppna denna publikation i ny flik eller fönster >>Spectral Mammography with X-Ray Optics and a Photon-Counting Detector
2009 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Early detection is vital to successfully treating breast cancer, and mammography screening is the most efficient and wide-spread method to reach this goal. Imaging low-contrast targets, while minimizing the radiation exposure to a large population is, however, a major challenge. Optimizing the image quality per unit radiation dose is therefore essential. In this thesis, two optimization schemes with respect to x-ray photon energy have been investigated: filtering the incident spectrum with refractive x-ray optics (spectral shaping), and utilizing the transmitted spectrum with energy-resolved photon-counting detectors (spectral imaging).

Two types of x-ray lenses were experimentally characterized, and modeled using ray tracing, field propagation, and geometrical optics. Spectral shaping reduced dose approximately 20% compared to an absorption-filtered reference system with the same signal-to-noise ratio, scan time, and spatial resolution. In addition, a focusing pre-object collimator based on the same type of optics reduced divergence of the radiation and improved photon economy by about 50%.

A photon-counting silicon detector was investigated in terms of energy resolution and its feasibility for spectral imaging. Contrast-enhanced tumor imaging with a system based on the detector was characterized and optimized with a model that took anatomical noise into account. Improvement in an ideal-observer detectability index by a factor of 2 to 8 over that obtained by conventional absorption imaging was found for different levels of anatomical noise and breast density. Increased conspicuity was confirmed by experiment. Further, the model was extended to include imaging of unenhanced lesions. Detectability of microcalcifications increased no more than a few percent, whereas the ability to detect large tumors might improve on the order of 50% despite the low attenuation difference between glandular and cancerous tissue. It is clear that inclusion of anatomical noise and imaging task in spectral optimization may yield completely different results than an analysis based solely on quantum noise.

Ort, förlag, år, upplaga, sidor
Stockholm: KTH, 2009. s. x, 56
Serie
Trita-FYS, ISSN 0280-316X ; 2009:69
Nyckelord
mammography; x-ray optics; photon counting; spectral shaping; spectral imaging; collimation; radiation dose; signal-to-noise ratio; quantum noise; anatomical noise; spatial resolution; x-ray flux;
Nationell ämneskategori
Teknik och teknologier Annan teknik Atom- och molekylfysik och optik Övrig annan teknik Elektroteknik och elektronik Medicinsk laboratorie- och mätteknik Radiologi och bildbehandling
Identifikatorer
urn:nbn:se:kth:diva-11641 (URN)978-91-7415-516-7 (ISBN)
Disputation
2009-12-18, Kollegiesalen, Lindstedtsvägen 26, KTH, Stockholm, 10:00 (Engelska)
Opponent
Handledare
Anmärkning
QC 20100714Tillgänglig från: 2009-12-04 Skapad: 2009-11-27 Senast uppdaterad: 2010-07-15Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopushttp://dx.doi.org/10.1118/1.3062926

Personposter BETA

Nillius, Peter

Sök vidare i DiVA

Av författaren/redaktören
Fredenberg, ErikCederström, BjörnÅslund, MagnusNillius, PeterDanielsson, Mats
Av organisationen
Medicinsk avbildningFysik
I samma tidskrift
Medical physics (Lancaster)
Övrig annan teknikAtom- och molekylfysik och optikRadiologi och bildbehandlingMedicinsk laboratorie- och mätteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 309 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf