Energy resolution of a photon-counting silicon strip detector
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk bildfysik. (Medical Imaging)ORCID-id: 0000-0002-0724-0205
Sectra Mamea AB, Smidesvägen 5, SE-171 41 Solna, Sweden.
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk bildfysik. (Medical Imaging)
Sectra Mamea AB, Smidesvägen 5, SE-171 41 Solna, Sweden.
Visa övriga samt affilieringar
2010 (Engelska)Ingår i: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, s. 156-162Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present study is optimization with respect to energy resolution. Factors relevant for the energy response were measured, simulated, or gathered from previous studies, and used as input parameters to a cascaded detector model. Threshold scans over several X-ray spectra were used to calibrate threshold levels to energy, and to validate the model. The energy resolution of the detector assembly was assessed to range over ΔE/E=0.12–0.26 in the mammography region. Electronic noise dominated the peak broadening, followed by charge sharing between adjacent detector strips, and a channel-to-channel threshold spread. The energy resolution may be improved substantially if these effects are reduced to a minimum. Anti-coincidence logic mitigated double counting from charge sharing, but erased the energy resolution of all detected events, and optimization of the logic is desirable. Pile-up was found to be of minor importance at typical mammography rates.

Ort, förlag, år, upplaga, sidor
2010. s. 156-162
Nyckelord [en]
Spectral X-ray imaging, Mammography; Silicon strip detector, Photon counting, Energy resolution, Cascaded detector model
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:kth:diva-11636DOI: 10.1016/j.nima.2009.10.152ISI: 000274772800023Scopus ID: 2-s2.0-77949279240OAI: oai:DiVA.org:kth-11636DiVA, id: diva2:278573
Anmärkning

QC 20100714

Tillgänglig från: 2009-11-27 Skapad: 2009-11-27 Senast uppdaterad: 2024-03-18Bibliografiskt granskad
Ingår i avhandling
1. Spectral Mammography with X-Ray Optics and a Photon-Counting Detector
Öppna denna publikation i ny flik eller fönster >>Spectral Mammography with X-Ray Optics and a Photon-Counting Detector
2009 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Early detection is vital to successfully treating breast cancer, and mammography screening is the most efficient and wide-spread method to reach this goal. Imaging low-contrast targets, while minimizing the radiation exposure to a large population is, however, a major challenge. Optimizing the image quality per unit radiation dose is therefore essential. In this thesis, two optimization schemes with respect to x-ray photon energy have been investigated: filtering the incident spectrum with refractive x-ray optics (spectral shaping), and utilizing the transmitted spectrum with energy-resolved photon-counting detectors (spectral imaging).

Two types of x-ray lenses were experimentally characterized, and modeled using ray tracing, field propagation, and geometrical optics. Spectral shaping reduced dose approximately 20% compared to an absorption-filtered reference system with the same signal-to-noise ratio, scan time, and spatial resolution. In addition, a focusing pre-object collimator based on the same type of optics reduced divergence of the radiation and improved photon economy by about 50%.

A photon-counting silicon detector was investigated in terms of energy resolution and its feasibility for spectral imaging. Contrast-enhanced tumor imaging with a system based on the detector was characterized and optimized with a model that took anatomical noise into account. Improvement in an ideal-observer detectability index by a factor of 2 to 8 over that obtained by conventional absorption imaging was found for different levels of anatomical noise and breast density. Increased conspicuity was confirmed by experiment. Further, the model was extended to include imaging of unenhanced lesions. Detectability of microcalcifications increased no more than a few percent, whereas the ability to detect large tumors might improve on the order of 50% despite the low attenuation difference between glandular and cancerous tissue. It is clear that inclusion of anatomical noise and imaging task in spectral optimization may yield completely different results than an analysis based solely on quantum noise.

Ort, förlag, år, upplaga, sidor
Stockholm: KTH, 2009. s. x, 56
Serie
Trita-FYS, ISSN 0280-316X ; 2009:69
Nyckelord
mammography; x-ray optics; photon counting; spectral shaping; spectral imaging; collimation; radiation dose; signal-to-noise ratio; quantum noise; anatomical noise; spatial resolution; x-ray flux;
Nationell ämneskategori
Teknik och teknologier Annan teknik Atom- och molekylfysik och optik Övrig annan teknik Elektroteknik och elektronik Medicinsk laboratorie- och mätteknik Radiologi och bildbehandling
Identifikatorer
urn:nbn:se:kth:diva-11641 (URN)978-91-7415-516-7 (ISBN)
Disputation
2009-12-18, Kollegiesalen, Lindstedtsvägen 26, KTH, Stockholm, 10:00 (Engelska)
Opponent
Handledare
Anmärkning
QC 20100714Tillgänglig från: 2009-12-04 Skapad: 2009-11-27 Senast uppdaterad: 2022-06-25Bibliografiskt granskad

Open Access i DiVA

fulltext(509 kB)257 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 509 kBChecksumma SHA-512
52eca604404c2ef00c0e3f304c9661acf046accfcd5a7d77e6b724dc56a22d856d097e382d27bef3e34cb511c458274c3887b47c241703281b8d42e027a1314a
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Fredenberg, ErikCederström, BjörnDanielsson, Mats

Sök vidare i DiVA

Av författaren/redaktören
Fredenberg, ErikCederström, BjörnDanielsson, Mats
Av organisationen
Medicinsk bildfysik
I samma tidskrift
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 257 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 805 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf