Energy filtering with x-ray lenses: Optimization for photon-counting mammography
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk avbildning.
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk avbildning. (Medical Imaging)
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk avbildning. (Medical Imaging)ORCID-id: 0000-0002-3039-9791
2010 (Engelska)Ingår i: Radiation Protection Dosimetry, ISSN 0144-8420, E-ISSN 1742-3406, Vol. 139, s. 339-342Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Chromatic properties of the multi-prism and prism-array x-ray lenses (MPL and PAL) can potentially be utilized for efficient energy filtering and dose reduction in mammography. The line-shaped foci of the lenses are optimal for coupling to photon-counting silicon strip detectors in a scanning system. A theoretical model was developed and used to investigate the benefit of two lenses compared to an absorption-filtered reference system. The dose reduction of the MPL filter was 15% compared to the reference system at matching scan time, and the spatial resolution was higher. The dose of the PAL-filtered system was found to be 20% lower than for the reference system at equal scan time and resolution, and only 20% higher than for a monochromatic beam. An investigation of some practical issues remains, including the feasibility of brilliant-enough x-ray sources and manufacturing of a polymer PAL.

Ort, förlag, år, upplaga, sidor
2010. Vol. 139, s. 339-342
Nyckelord [en]
x-ray imaging, mammography, x-ray optics, multiprism lens, prism-array lens, energy filtering, radiation dose, spatial resolution, exposure time
Nationell ämneskategori
Övrig annan teknik Atom- och molekylfysik och optik Radiologi och bildbehandling Medicinsk laboratorie- och mätteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-11640DOI: 10.1093/rpd/ncq049ISI: 000277738200064Scopus ID: 2-s2.0-77953329327OAI: oai:DiVA.org:kth-11640DiVA, id: diva2:278580
Anmärkning
QC 20100714. Uppdaterad från submitted till published (20100714)Tillgänglig från: 2009-11-27 Skapad: 2009-11-27 Senast uppdaterad: 2017-12-12Bibliografiskt granskad
Ingår i avhandling
1. Spectral Mammography with X-Ray Optics and a Photon-Counting Detector
Öppna denna publikation i ny flik eller fönster >>Spectral Mammography with X-Ray Optics and a Photon-Counting Detector
2009 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Early detection is vital to successfully treating breast cancer, and mammography screening is the most efficient and wide-spread method to reach this goal. Imaging low-contrast targets, while minimizing the radiation exposure to a large population is, however, a major challenge. Optimizing the image quality per unit radiation dose is therefore essential. In this thesis, two optimization schemes with respect to x-ray photon energy have been investigated: filtering the incident spectrum with refractive x-ray optics (spectral shaping), and utilizing the transmitted spectrum with energy-resolved photon-counting detectors (spectral imaging).

Two types of x-ray lenses were experimentally characterized, and modeled using ray tracing, field propagation, and geometrical optics. Spectral shaping reduced dose approximately 20% compared to an absorption-filtered reference system with the same signal-to-noise ratio, scan time, and spatial resolution. In addition, a focusing pre-object collimator based on the same type of optics reduced divergence of the radiation and improved photon economy by about 50%.

A photon-counting silicon detector was investigated in terms of energy resolution and its feasibility for spectral imaging. Contrast-enhanced tumor imaging with a system based on the detector was characterized and optimized with a model that took anatomical noise into account. Improvement in an ideal-observer detectability index by a factor of 2 to 8 over that obtained by conventional absorption imaging was found for different levels of anatomical noise and breast density. Increased conspicuity was confirmed by experiment. Further, the model was extended to include imaging of unenhanced lesions. Detectability of microcalcifications increased no more than a few percent, whereas the ability to detect large tumors might improve on the order of 50% despite the low attenuation difference between glandular and cancerous tissue. It is clear that inclusion of anatomical noise and imaging task in spectral optimization may yield completely different results than an analysis based solely on quantum noise.

Ort, förlag, år, upplaga, sidor
Stockholm: KTH, 2009. s. x, 56
Serie
Trita-FYS, ISSN 0280-316X ; 2009:69
Nyckelord
mammography; x-ray optics; photon counting; spectral shaping; spectral imaging; collimation; radiation dose; signal-to-noise ratio; quantum noise; anatomical noise; spatial resolution; x-ray flux;
Nationell ämneskategori
Teknik och teknologier Annan teknik Atom- och molekylfysik och optik Övrig annan teknik Elektroteknik och elektronik Medicinsk laboratorie- och mätteknik Radiologi och bildbehandling
Identifikatorer
urn:nbn:se:kth:diva-11641 (URN)978-91-7415-516-7 (ISBN)
Disputation
2009-12-18, Kollegiesalen, Lindstedtsvägen 26, KTH, Stockholm, 10:00 (Engelska)
Opponent
Handledare
Anmärkning
QC 20100714Tillgänglig från: 2009-12-04 Skapad: 2009-11-27 Senast uppdaterad: 2010-07-15Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Fredenberg, ErikCederström, BjörnDanielsson, Mats
Av organisationen
Medicinsk avbildning
I samma tidskrift
Radiation Protection Dosimetry
Övrig annan teknikAtom- och molekylfysik och optikRadiologi och bildbehandlingMedicinsk laboratorie- och mätteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 446 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf