Confocal pH imaging of microscopic specimens using fluorescence lifetimes and phase fluorometry: influence of parameter choice on system performance
KTH, Tidigare Institutioner                               , Fysik.
2000 (Engelska)Ingår i: Journal of Microscopy, ISSN 0022-2720, E-ISSN 1365-2818, Vol. 199, s. 106-114Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

We investigate the performance of confocal pH imaging when using phase fluorometry and fluorophores with pH-dependent lifetimes. In these experiments, the specimen is illuminated by a laser beam, whose intensity is sinusoidally modulated. The lifetime-dependent phase shift in the fluorescent signal is detected by a lock-in amplifier, and converted into a pH value through a calibration procedure. A theoretical investigation is made of how the different system parameters will influence the results concerning sensitivity and noise. Experiments carried out with the fluorophore SNAFL-2 support these theoretical predictions. It is found that, under realistic experimental conditions, we can expect a pH change of 0.1 units to be easily detected in an 8-bit digital image. However, the pixel-to-pixel root mean square noise is often of the order of one pH unit. This comparatively high level of noise has its origin in photon quantum noise. pH measurements on living cells show a systematic deviation from expected values. This discrepancy appears to be the result of fluorophore interaction with various cell constituents, and is the subject of further investigation.

Ort, förlag, år, upplaga, sidor
2000. Vol. 199, s. 106-114
Nyckelord [en]
confocal microscopy, fluorescence lifetime imaging, pH measurements, time-resolved identification, scanning ims technique, multiple fluorophores, laser, cells, indicators, molecules, neurons
Identifikatorer
URN: urn:nbn:se:kth:diva-19976ISI: 000088807300004OAI: oai:DiVA.org:kth-19976DiVA, id: diva2:338669
Anmärkning
QC 20100525Tillgänglig från: 2010-08-10 Skapad: 2010-08-10 Senast uppdaterad: 2017-12-12Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Personposter BETA

Brismar, Hjalmar

Sök vidare i DiVA

Av författaren/redaktören
Carlsson, KjellBrismar, Hjalmar
Av organisationen
Fysik
I samma tidskrift
Journal of Microscopy

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 53 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf