Burst technology with feedback-loop control for capacitive detection and electrostatic excitation of resonant silicon sensors
Vise andre og tillknytning
2000 (engelsk)Inngår i: IEEE Transactions on Electron Devices, ISSN 0018-9383, E-ISSN 1557-9646, Vol. 47, nr 11, s. 2228-2235Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A method for excitation and detection of resonant silicon sensors based on discontinuous, burst excitation is presented. The solution eliminates the crosstalk between electrostatic excitation and capacitive detection by separating them in time. High excitation voltages can be combined with highly sensitive detection electronics. The method facilitates the use of large distances between the resonator and electrodes used for elicitation and detection. The method was successfully tested with feedback-loop control on silicon resonant density and pressure sensors where the electrodes were positioned outside a glass, Continuous measurements of gas pressures and liquid densities were realized, The simplified fabrication process utilized reduces the risk of leakage from the ambient pressure to the low-pressure cavities in which the resonators are encapsulated since electrical feedthroughs are not needed, Excitation voltages alternating between 0 and 150 V could be applied to the resonators with measured electronics sensitivities of 0.4 fF Signal-to-noise ratios (SNRs) as high as 100 (density sensor) and 360 (pressure sensor) were obtained. The electronic evaluation revealed that the burst duty cycle (i.e,, the excitation time relative to the free oscillation time) had a strong influence on the output detection voltage, As few as two excitation periods with a burst cycle frequency of 115 Hz and a burst duty cycle of 1% was sufficient to select and lock the resonance frequency (28 042 Hz) for the tested pressure sensor. The same electrodes could be used for both excitation and detection, A novel solution is also presented that eliminates the charging effect of dielectric surfaces which otherwise can be a problem for capacitive detection.

sted, utgiver, år, opplag, sider
2000. Vol. 47, nr 11, s. 2228-2235
Emneord [en]
burst electronics, capacitive detection, discontinuous excitation, electrostatic excitation, feedback control, switching, density sensor, vibration
Identifikatorer
URN: urn:nbn:se:kth:diva-20131DOI: 10.1109/16.877188ISI: 000090135700029OAI: oai:DiVA.org:kth-20131DiVA, id: diva2:338824
Merknad
QC 20100525Tilgjengelig fra: 2010-08-10 Laget: 2010-08-10 Sist oppdatert: 2017-12-12bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Stemme, Göran

Søk i DiVA

Av forfatter/redaktør
Stemme, Göran
Av organisasjonen
I samme tidsskrift
IEEE Transactions on Electron Devices

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 54 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf