Modeling and Simulation of Wide Area Monitoring and Control Systems in IP-based Networks
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.ORCID-id: 0000-0003-3014-5609
2009 (engelsk)Inngår i: 2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, New York, USA: IEEE , 2009, s. 2514-2521Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Phasor based Wide Area Monitoring and Control Systems (WAMC) is becoming a reality with increased international research and development. Many aspects of these systems are being addressed and researched. These systems depend largely on high performance communication architecture. This paper addresses the analysis of PMU systems and communication architectures by utilizing simulation tools to implement and analyze models. Specifically, focusing on the transmission of Phasor samples to the Phasor Data Concentrator (PDC) and control signals from the WAMC systems back to substations devices. This done by implementing shared and dedicated communication network scenarios to analyze delays. This is the first step to analyzing the performance and scalability of the IT infrastructure to support PMU-based Systems.

sted, utgiver, år, opplag, sider
New York, USA: IEEE , 2009. s. 2514-2521
Serie
IEEE Power and Energy Society General Meeting-PESGM
Emneord [en]
PMU Communication, Wide Area Monitoring and Control, communication simulation, PMU communication delays
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-25158DOI: 10.1109/PES.2009.5275818ISI: 000275524901080Scopus ID: 2-s2.0-77649297519ISBN: 978-1-4244-4240-9 (tryckt)OAI: oai:DiVA.org:kth-25158DiVA, id: diva2:356161
Konferanse
General Meeting of the IEEE-Power-and-Energy-Society, Calgary, CANADA, JUL 26-30, 2009
Merknad
QC 20101011Tilgjengelig fra: 2010-10-11 Laget: 2010-10-11 Sist oppdatert: 2018-01-12bibliografisk kontrollert
Inngår i avhandling
1. Wide area monitoring and control systems - application communication requirements and simulation
Åpne denne publikasjonen i ny fane eller vindu >>Wide area monitoring and control systems - application communication requirements and simulation
2009 (engelsk)Licentiatavhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Today’s electrical transmission & distribution systems, are facing a number of challenges related to changing environmental, technical and business factors. Among these factors are, increased environmental restrictions leading to higher share of production from renewable and uncontrollable sources as well as local environmental concerns regarding construction of new transmission and distribution lines. The re-regulation of the electricity market has created a dynamic environment in which multiple organizations have to coordinate and cooperate in the operation and control of the power system. Finally, the high rate of devel-opment within the ICT field is creating many new opportunities for power system opera-tion and control, thanks to introduction of new technologies for measurement, communi-cation and automation.

As a result of these factors, Wide Area Monitoring and Control (WAMC) systems have been proposed. WAMC systems utilize new ICT based technologies to offer more accurate and timely data on the state of the power system. WAMC systems utilize Phasor Measure-ment Units (PMUs) that have higher data rates and are time synchronised using, GPS satel-lites. This allows synchronized observation of the dynamics of the power system, making it possible to manage the system at a more efficient and responsive level and apply wide area control and protection schemes. The success WAMC systems, on the other hand, are largely dependent on the performance of the Information and Communication Technology (ICT) infrastructure that would support them.

This thesis investigates the requirements on, and suitability of the ICT systems that support WAMC systems. This was done by identifying WAMC applications and the elicitation of their requirements. Furthermore, a set of simulation projects were carried out to determine the communication system characteristics such as delay and the impact of this delay on the WAMC system.

This thesis has several contributions. First, it provides summary and analysis of WAMC application priorities and requirements in the Nordic region. Secondly it provides simula-tion based comparison and evaluation of communication paradigms for WAMC systems. The research documented in this thesis addresses these paradigms by providing a compari-son and evaluation through simulation. Thirdly, the thesis provides insight to the possible sources of delay in WAMC architecture and the impact of these delays on data quality specifically data incompleteness. This provides insight on what applications are important to practitioners and what is the expected performance of these applications, as seen from the power system control and operation point of view.

sted, utgiver, år, opplag, sider
Stockholm: KTH, 2009. s. viii, 117
Serie
Trita-EE, ISSN 1653-5146 ; 2009:045
Emneord
Wide Area Monitoring and Control systems, Phasor Measurements Units, Power System Communication, SCADA systems
Identifikatorer
urn:nbn:se:kth:diva-11316 (URN)
Presentation
2009-11-06, Seminarierummet, KTH, Osquldas väg 12, Stockholm, 10:00 (engelsk)
Tilgjengelig fra: 2009-10-22 Laget: 2009-10-22 Sist oppdatert: 2010-10-11bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Nordström, Lars

Søk i DiVA

Av forfatter/redaktør
Chenine, MoustafaKaram, EliasNordström, Lars
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 403 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf