Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Evidence and implications of the background phosphorus concentration of submerged aquatic vegetation wetlands in Stormwater Treatment Areas for Everglades restoration
KTH, Skolan för arkitektur och samhällsbyggnad (ABE), Mark- och vattenteknik. (Ekosystemteknik)
2011 (engelsk)Inngår i: Water resources research, ISSN 0043-1397, E-ISSN 1944-7973, Vol. 47, s. W01511-Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The limits of phosphorus (P) removal from the 18,120 ha Stormwater Treatment Areas (STAs) for Everglades restoration depend largely on the performance of submerged aquatic vegetation (SAV) wetlands, as SAV treatment cells now provide final stage treatment for 85% of the STA project. A long-term internal P profile in STA-2 cell 3 (STA2C3), one of the longest-running and best performing SAV cells, demonstrated no further net removal in the back quarter of the cell once total P (TP) levels approached 15 mu g L-1. Inflow-outflow performance data from STA2C3 were analyzed at monthly and annual scales and were pooled with data from an additional eight STA SAV treatment cells. The pooled data allowed inference of background TP concentrations in SAV treatment cells using existing Bayesian methods. Results showed a central tendency of 16 mu g L-1(13 - 17, 90% bounds), insensitivity to P loads less than similar to 1.7 g m(-2) yr(-1), and interannual variability outside these bounds. Internal data from the STA2C3 profile provided validation. Background P concentrations of 7 and 6 mu g L-1 were identified for dissolved organic and particulate P fractions in the data pool, respectively, again similar to values in the STA2C3 gradient. Existing simulation modeling approaches for STA evaluations were identified as ineffective at or near background TP concentrations. Instead, we use an empirical and probabilistic approach based on full-scale data from STAs that produces annual risk of exceedance statistics and is easy to update. The current analysis suggests tangible risks for exceeding proposed annual discharge criteria from the STAs in the range of 16-20 mu g L-1.

sted, utgiver, år, opplag, sider
2011. Vol. 47, s. W01511-
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-30495DOI: 10.1029/2010WR009294ISI: 000286772700002Scopus ID: 2-s2.0-79551671893OAI: oai:DiVA.org:kth-30495DiVA, id: diva2:401804
Merknad
QC 20110303Tilgjengelig fra: 2011-03-04 Laget: 2011-02-28 Sist oppdatert: 2017-12-11bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Søk i DiVA

Av forfatter/redaktør
Juston, John M.
Av organisasjonen
I samme tidsskrift
Water resources research

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 32 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf