Analysis of a two-phase non-isothermal model for a PEFC
KTH, Skolan för teknikvetenskap (SCI), Mekanik. KTH, Skolan för teknikvetenskap (SCI), Centra, FaxénLaboratoriet.
KTH, Skolan för teknikvetenskap (SCI), Mekanik. KTH, Skolan för teknikvetenskap (SCI), Centra, FaxénLaboratoriet.ORCID-id: 0000-0002-8318-1251
2005 (Engelska)Ingår i: Journal of the Electrochemical Society, ISSN 0013-4651, E-ISSN 1945-7111, Vol. 152, nr 5, s. A1021-A1034Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A non-isothermal, two-phase model for a polymer electrolyte fuel cell (PEFC) is presented, analyzed, and solved numerically under three different thermal, and two hydrodynamic, modeling assumptions; the consequences of these are then discussed in terms of thermal and water management and cell performance. The study is motivated by recent experimental results that suggest the presence of previously unreported, and thus unmodeled, thermal contact resistances between the components of PEFCs and the discrepancy in the value for the capillary pressure that is used by different authors when modeling the two-phase flow in PEFCs. For the three different thermal assumptions (assuming effective heat conductivities, isothermal flow, and interfacial and bulk conductivites), liquid saturations of around 10% are obtained at the cathode active layer for 1000 mA cm(-2) and a cell voltage of 0.6 V. When lowering the capillary pressure (hydrodynamic assumption), liquid saturations of almost 30% and locally up to 100% are observed at the active layer of the cathode. At this current density and voltage, temperature differences across the cell of around 9 degrees C are predicted. In addition, the effect of varying clamping pressure within the framework of the model is touched upon. The benefits of the scaling analysis conducted here, to predict correctly, prior to numerical computations, important characteristic cell performance quantities such as current density and temperature drop are also highlighted.

Ort, förlag, år, upplaga, sidor
2005. Vol. 152, nr 5, s. A1021-A1034
Nationell ämneskategori
Maskinteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-37736DOI: 10.1149/1.1877992ISI: 000228521400025Scopus ID: 2-s2.0-20344401539OAI: oai:DiVA.org:kth-37736DiVA, id: diva2:435046
Tillgänglig från: 2011-08-17 Skapad: 2011-08-17 Senast uppdaterad: 2022-06-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Vynnycky, Michael

Sök vidare i DiVA

Av författaren/redaktören
Birgersson, ErikVynnycky, Michael
Av organisationen
MekanikFaxénLaboratoriet
I samma tidskrift
Journal of the Electrochemical Society
Maskinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 317 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf