Contrast-enhanced dual-energy subtraction imaging using electronic spectrum-splitting and multi-prism x-ray lenses
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk avbildning.
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk avbildning.
Visa övriga samt affilieringar
2008 (Engelska)Ingår i: Medical Imaging 2008 - Physics of Medical Imaging: PTS 1-3 / [ed] Hsieh, J; Samei, E, 2008, Vol. 6913, s. 91310-91310Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Dual-energy subtraction imaging (DES) is a method to improve the detectability of contrast agents over a lumpy background. Two images, acquired at x-ray energies above and below an absorption edge of the agent material, are logarithmically subtracted, resulting in suppression of the signal from the tissue background and a relative enhancement of the signal from the agent. Although promising, DES is still not widely used in clinical practice. One reason may be the need for two distinctly separated x-ray spectra that are still close to the absorption edge, realized through dual exposures which may introduce motion unsharpness. In this study, electronic spectrum-splitting with a silicon-strip detector is theoretically and experimentally investigated for a mammography model with iodinated contrast agent. Comparisons are made to absorption imaging and a near-ideal detector using a signal-to-noise ratio that includes both statistical and structural noise. Similar to previous studies, heavy absorption filtration was needed to narrow the spectra at the expense of a large reduction in x-ray flux. Therefore, potential improvements using a chromatic multi-prism x-ray lens (MPL) for filtering were evaluated theoretically. The MPL offers a narrow tunable spectrum, and we show that the image quality can be improved compared to conventional filtering methods.

Ort, förlag, år, upplaga, sidor
2008. Vol. 6913, s. 91310-91310
Serie
Progress in Biomedical Optics and Imaging - Proceedings of SPIE, ISSN 0277-786X ; 6913
Nyckelord [en]
mammography, contrast-enhanced, dual-energy subtraction, x-ray optics, multi-prism lens, energy filtering
Nationell ämneskategori
Biomedicinsk laboratorievetenskap/teknologi
Identifikatorer
URN: urn:nbn:se:kth:diva-38400DOI: 10.1117/12.770501ISI: 000256660300034Scopus ID: 2-s2.0-43149123146ISBN: 978-0-8194-7097-3 (tryckt)OAI: oai:DiVA.org:kth-38400DiVA, id: diva2:437824
Konferens
Medical Imaging 2008 - Physics of Medical Imaging; San Diego, CA; 18 February 2008 through 21 February 2008
Tillgänglig från: 2011-08-30 Skapad: 2011-08-25 Senast uppdaterad: 2011-08-30Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Fredenberg, ErikCederström, BjörnDanielsson, Mats
Av organisationen
Medicinsk avbildning
Biomedicinsk laboratorievetenskap/teknologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 250 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf