Optimization of mammography with respect to anatomical noise
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk avbildning.
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk avbildning.ORCID-id: 0000-0002-3039-9791
Visa övriga samt affilieringar
2011 (Engelska)Ingår i: MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING / [ed] Pelc, NJ; Samei, E; Nishikawa, RM, 2011, Vol. 7961Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Beam quality optimization in mammography traditionally considers detection of a target obscured by quantum noise on a homogenous background. It can be argued that this scheme does not correspond well to the clinical imaging task because real mammographic images contain a complex superposition of anatomical structures, resulting in anatomical noise that may dominate over quantum noise. Using a newly developed spectral mammography system, we measured the correlation and magnitude of the anatomical noise in a set of mammograms. The results from these measurements were used as input to an observer-model optimization that included quantum noise as well as anatomical noise. We found that, within this framework, the detectability of tumors and microcalcifications behaved very differently with respect to beam quality and dose. The results for small microcalcifications were similar to what traditional optimization methods would yield, which is to be expected since quantum noise dominates over anatomical noise at high spatial frequencies. For larger tumors, however, low-frequency anatomical noise was the limiting factor. Because anatomical structure has similar energy dependence as tumor contrast, optimal x-ray energy was significantly higher and the useful energy region wider than traditional methods suggest. Measurements on a tissue phantom confirmed these theoretical results. Furthermore, since quantum noise constitutes only a small fraction of the noise, the dose could be reduced substantially without sacrificing tumor detectability. Exposure settings used clinically are therefore not necessarily optimal for this imaging task. The impact of these findings on the mammographic imaging task as a whole is, however, at this stage unclear.

Ort, förlag, år, upplaga, sidor
2011. Vol. 7961
Serie
Proceedings of SPIE, ISSN 0277-786X ; 7961
Nyckelord [en]
mammography, optimization, beam quality, observer model, anatomical noise, quantum noise, spectral imaging, glandularity
Nationell ämneskategori
Fysik
Identifikatorer
URN: urn:nbn:se:kth:diva-41309DOI: 10.1117/12.877985ISI: 000294178500034Scopus ID: 2-s2.0-79955748369OAI: oai:DiVA.org:kth-41309DiVA, id: diva2:443882
Konferens
Conference on Medical Imaging 2011 - Physics of Medical Imaging, Lake Buena Vista, FL, FEB 13-17, 2011
Anmärkning
QC 20110927Tillgänglig från: 2011-09-27 Skapad: 2011-09-26 Senast uppdaterad: 2011-09-27Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Fredenberg, ErikDanielsson, MatsCederström, Björn
Av organisationen
Medicinsk avbildning
Fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 41 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf