Optimization of mammography with respect to anatomical noise
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk bildfysik.ORCID-id: 0000-0002-0724-0205
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk bildfysik.ORCID-id: 0000-0002-3039-9791
General Hospital of Pistoia (Italy) .
Visa övriga samt affilieringar
2011 (Engelska)Ingår i: Medical Imaging 2011: Physics of Medical Imaging / [ed] Pelc, NJ; Samei, E; Nishikawa, RM, 2011, Vol. 7961, artikel-id 796112Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Beam quality optimization in mammography traditionally considers detection of a target obscured by quantum noise on a homogenous background. It can be argued that this scheme does not correspond well to the clinical imaging task because real mammographic images contain a complex superposition of anatomical structures, resulting in anatomical noise that may dominate over quantum noise. Using a newly developed spectral mammography system, we measured the correlation and magnitude of the anatomical noise in a set of mammograms. The results from these measurements were used as input to an observer-model optimization that included quantum noise as well as anatomical noise. We found that, within this framework, the detectability of tumors and microcalcifications behaved very differently with respect to beam quality and dose. The results for small microcalcifications were similar to what traditional optimization methods would yield, which is to be expected since quantum noise dominates over anatomical noise at high spatial frequencies. For larger tumors, however, low-frequency anatomical noise was the limiting factor. Because anatomical structure has similar energy dependence as tumor contrast, optimal x-ray energy was significantly higher and the useful energy region wider than traditional methods suggest. Measurements on a tissue phantom confirmed these theoretical results. Furthermore, since quantum noise constitutes only a small fraction of the noise, the dose could be reduced substantially without sacrificing tumor detectability. Exposure settings used clinically are therefore not necessarily optimal for this imaging task. The impact of these findings on the mammographic imaging task as a whole is, however, at this stage unclear.

Ort, förlag, år, upplaga, sidor
2011. Vol. 7961, artikel-id 796112
Serie
Proceedings of SPIE, ISSN 0277-786X ; 7961
Nyckelord [en]
mammography, optimization, beam quality, observer model, anatomical noise, quantum noise, spectral imaging, glandularity
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:kth:diva-41309DOI: 10.1117/12.877985ISI: 000294178500034Scopus ID: 2-s2.0-79955748369OAI: oai:DiVA.org:kth-41309DiVA, id: diva2:443882
Konferens
Medical Imaging 2011 - Physics of Medical Imaging, Lake Buena Vista, FL, FEB 13-17, 2011
Anmärkning

QC 20110927

Tillgänglig från: 2011-09-27 Skapad: 2011-09-26 Senast uppdaterad: 2024-03-18Bibliografiskt granskad

Open Access i DiVA

fulltext(2003 kB)98 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2003 kBChecksumma SHA-512
f6c0ce3e9be08c70291ca2c31b4810a60037b4ad12ae759a3fbebb4c8060947abcc1965cd47be1a938d8a04b04121e36de69cfb053df00b88f857059c2db629b
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Fredenberg, ErikDanielsson, MatsCederström, Björn

Sök vidare i DiVA

Av författaren/redaktören
Fredenberg, ErikDanielsson, MatsCederström, Björn
Av organisationen
Medicinsk bildfysik
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 98 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 101 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf