Optimization of operating conditions in photon counting multi-slit mammography based on Si-strip detectors - art. no. 61420A
KTH, Skolan för teknikvetenskap (SCI), Fysik.
KTH, Skolan för teknikvetenskap (SCI), Fysik.
KTH, Skolan för teknikvetenskap (SCI), Fysik.ORCID-id: 0000-0002-3039-9791
2006 (Engelska)Ingår i: Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3 / [ed] Flynn, MJ; Hsieh, J, 2006, Vol. 6142, s. A1420-A1420Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Measurements and simulations of the signal-difference-to-noise ratio (SDNR) and average glandular dose (AGD) have been performed on a photon counting full-field digital mammography system to determine the optimal operating conditions. Several beam qualities were experimentally evaluated by using different combinations of tube voltage, added filters and thickness of BR12 with a tungsten target x-ray tube. The SDNR and AGD were also calculated theoretically for an extended number of operating conditions and a more accurate breast model. As figure of merit for each operating condition, a spectral quantum efficiency (SQE) was calculated as the polychromatic SDNR squared over the optimal monochromatic SDNR squared at the same AGD. The theoretical model agreed within 4% relative the measured SDNR throughout the evaluated breast thickness (30-70 mm) and tube voltage range (26-38 kV). The optimization was performed with a constant SDNR-rate as compared to using a fixed filter thickness. The optimal combinations of tube voltage-filter material were: 32 kV-Ag, 34 kV-Cd, 36 kV-Sn for a breast thickness of 30, 50 and 70 mm respectively. These K-edge filter materials increased the SQE by less than 4% compared to the optimal Al filtration.

Ort, förlag, år, upplaga, sidor
2006. Vol. 6142, s. A1420-A1420
Serie
PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS (SPIE), ISSN 0277-786X ; 6142
Nyckelord [en]
mammography, photon counting, spectrum, filter, optimization
Nationell ämneskategori
Atom- och molekylfysik och optik
Identifikatorer
URN: urn:nbn:se:kth:diva-41967DOI: 10.1117/12.652728ISI: 000238049700008Scopus ID: 2-s2.0-33745344040ISBN: 978-081946185-8 (tryckt)OAI: oai:DiVA.org:kth-41967DiVA, id: diva2:445669
Konferens
Medical Imaging 2006 Conference. San Diego, CA. FEB 12-14, 2006
Anmärkning
QC 20111004Tillgänglig från: 2011-10-04 Skapad: 2011-10-04 Senast uppdaterad: 2011-10-04Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Åslund, MagnusCederström, BjörnDanielsson, Mats
Av organisationen
Fysik
Atom- och molekylfysik och optik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 80 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf