Tumor localization and image registration of 18-FDG SPECT scans with CT scans
New York University.
New York University.
New York University.
New York University.
Vise andre og tillknytning
1999 (engelsk)Inngår i: Journal of Nuclear Medicine, ISSN 0161-5505, E-ISSN 1535-5667, Vol. 40, nr 5, s. 290P-291PArtikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

PURPOSE:

The aim of this study was to determine the feasibility of registering routine clinical F-18 fluorodeoxyglucose (FDG) coincidence detection (CD) scans with computed tomographic (CT) scans for radiation treatment planning and case management.

METHODS:

F-18 FDG CD and chest CT scans, performed in 10 randomly selected patients with confirmed or possible adenocarcinoma of the lung, were evaluated. The quality of the matches was verified by comparisons of the center-to-center distance between a region of interest (ROI) manually drawn on the CT slice and warped onto the CD slice with an ROI drawn manually directly on the CD slice. In addition, the overlap between the two ROIs was calculated.

RESULTS:

All 10 F-18 FDG CD and CT scans were registered with good superimposition of soft tissue density on increased radionuclide activity. The center-to-center distance between the ROIs ranged from 0.29 mm to 8.08 mm, with an average center-to-center distance of 3.89 mm +/- 2.42 mm (0.69 pixels +/- 0.34 pixels). The ROI overlap ranged from 77% to 99%, with an average of 90% +/- 5.6%.

CONCLUSIONS:

Although the use of F-18 FDG CD shows great promise for the identification of tumors, it shares the same drawbacks as those associated with radiolabeled monoclonal antibody SPECT and ligand-based positron emission tomographic scans in that anatomic markers are limited. This study shows that image registration is feasible and may improve the clinical relevance of CD images.

sted, utgiver, år, opplag, sider
Society of Nuclear Medicine , 1999. Vol. 40, nr 5, s. 290P-291P
HSV kategori
Forskningsprogram
SRA - Informations- och kommunikationsteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-47861OAI: oai:DiVA.org:kth-47861DiVA, id: diva2:456483
Merknad
QC 20111115 Published abstract NR 20140804Tilgjengelig fra: 2011-11-14 Laget: 2011-11-14 Sist oppdatert: 2017-12-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Personposter BETA

Maguire Jr., Gerald Q.

Søk i DiVA

Av forfatter/redaktør
Maguire Jr., Gerald Q.
Av organisasjonen
I samme tidsskrift
Journal of Nuclear Medicine

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 577 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf