Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Small-animal tomography with a liquid-metal-jet x-ray source
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Biomedicinsk fysik och röntgenfysik.ORCID-id: 0000-0002-9487-669X
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Biomedicinsk fysik och röntgenfysik.ORCID-id: 0000-0001-7637-1850
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Biomedicinsk fysik och röntgenfysik.
Vise andre og tillknytning
2012 (engelsk)Inngår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE, SPIE - International Society for Optical Engineering, 2012, Vol. 8313, s. 83130N-Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

X-ray tomography of small animals is an important tool for medical research. For high-resolution x-ray imaging of few-cm-thick samples such as, e.g., mice, high-brightness x-ray sources with energies in the few-10-keV range are required. In this paper we perform the first small-animal imaging and tomography experiments using liquid-metal-jet-anode x-ray sources. This type of source shows promise to increase the brightness of microfocus x-ray systems, but present sources are typically optimized for an energy of 9 keV. Here we describe the details of a high-brightness 24-keV electron-impact laboratory microfocus x-ray source based on continuous operation of a heated liquid-In/Ga-jet anode. The source normally operates with 40 W of electron-beam power focused onto the metal jet, producing a 7×7 μm 2 FWHM x-ray spot. The peak spectral brightness is 4 × 10 9 photons/( s × mm 2 × mrad 2 × 0.1%BW) at the 24.2 keV In K α line. We use the new In/Ga source and an existing Ga/In/Sn source for high-resolution imaging and tomography of mice.

sted, utgiver, år, opplag, sider
SPIE - International Society for Optical Engineering, 2012. Vol. 8313, s. 83130N-
Serie
Progress in Biomedical Optics and Imaging, ISSN 1605-7422 ; 8313
Emneord [en]
liquid-metal-jet-anode, mouse, Small-animal imaging, tomography, x-ray
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-98179DOI: 10.1117/12.910777ISI: 000304768000021Scopus ID: 2-s2.0-84860385685ISBN: 978-081948962-3 (tryckt)OAI: oai:DiVA.org:kth-98179DiVA, id: diva2:536101
Konferanse
Medical Imaging 2012: Physics of Medical Imaging;San Diego, CA;5 February 2012 through 8 February 2012
Merknad
QC 20120621Tilgjengelig fra: 2012-06-21 Laget: 2012-06-20 Sist oppdatert: 2014-01-14bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Larsson, Daniel H.Lundström, UlfBurvall, AnnaHertz, Hans M.

Søk i DiVA

Av forfatter/redaktør
Larsson, Daniel H.Lundström, UlfTakman, PerBurvall, AnnaHertz, Hans M.
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 85 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf