Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Photon-Counting Spectral Phase-Contrast Mammography
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk avbildning.
Visa övriga samt affilieringar
2012 (Engelska)Ingår i: Medical Imaging 2012: Physics Of Medical Imaging / [ed] Pelc, NJ; Nishikawa, RM; Whiting, BR, SPIE - International Society for Optical Engineering, 2012, s. 83130F-Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Phase-contrast imaging is an emerging technology that may increase the signal-difference-to-noise ratio in medical imaging. One of the most promising phase-contrast techniques is Talbot interferometry, which, combined with energy-sensitive photon-counting detectors, enables spectral differential phase-contrast mammography. We have evaluated a realistic system based on this technique by cascaded-systems analysis and with a task-dependent ideal-observer detectability index as a figure-of-merit. Beam-propagation simulations were used for validation and illustration of the analytical framework. Differential phase contrast improved detectability compared to absorption contrast, in particular for fine tumor structures. This result was supported by images of human mastectomy samples that were acquired with a conventional detector. The optimal incident energy was higher in differential phase contrast than in absorption contrast when disregarding the setup design energy. Further, optimal weighting of the transmitted spectrum was found to have a weaker energy dependence than for absorption contrast. Taking the design energy into account yielded a superimposed maximum on both detectability as a function of incident energy, and on optimal weighting. Spectral material decomposition was not facilitated by phase contrast, but phase information may be used instead of spectral information.

Ort, förlag, år, upplaga, sidor
SPIE - International Society for Optical Engineering, 2012. s. 83130F-
Serie
Proceedings of SPIE, ISSN 0277-786X ; 8313
Nyckelord [en]
mammography, phase contrast, spectral imaging, detectability index, Talbot interferometry, photon counting
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:kth:diva-99499DOI: 10.1117/12.910615ISI: 000304768000013Scopus ID: 2-s2.0-84860387803ISBN: 978-0-8194-8962-3 (tryckt)OAI: oai:DiVA.org:kth-99499DiVA, id: diva2:542361
Konferens
Conference on Medical Imaging - Physics of Medical Imaging, FEB 05-08, 2012, San Diego, CA
Anmärkning
QC 20120731Tillgänglig från: 2012-07-31 Skapad: 2012-07-31 Senast uppdaterad: 2012-07-31Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Fredenberg, ErikDanielsson, Mats
Av organisationen
Medicinsk avbildning
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 65 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf