Test platform for synchrophasor based wide-area monitoring and control applications
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.ORCID-id: 0000-0003-4386-3781
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.
Jordan University of Science and Technology.
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.ORCID-id: 0000-0002-6590-6634
Vise andre og tillknytning
2013 (engelsk)Inngår i: Power and Energy Society General Meeting (PES), 2013 IEEE, Vancouver: IEEE , 2013, s. 6672308-Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Synchrophasor technology is considered as a main enabler for the envisioned Smart Grid at the transmission level. Despite some preliminary field test results reported from China Southern Grid, the majority of the synchrophasor applications are still in the engineering or advanced laboratory tests phases. One possible impedance of any real-life adoption of such applicationsis a lack of test platforms that are able to verify the proposed application paradigms in cost efficient manners, and also to demonstrate the interactions between the power system and the supporting ICT systems with sufficient details. In this paper, we report on the continuing research efforts targeting at developing a test platform for the development of the synchrophasor based applications. The platform incorporates a virtual Phasor Measurement Unit (PMU), a real-time simulator for power systems, a real-time simulator for communication networks, and an implementation of an open-source Phasor Data Concentrator. Specifically, this article focuses on the implementation and verification of the virtual PMU, and on the extension of its functionality to incorporate communication over UDP.

sted, utgiver, år, opplag, sider
Vancouver: IEEE , 2013. s. 6672308-
Serie
IEEE Power and Energy Society General Meeting PESGM, ISSN 1944-9925
Emneord [en]
Cost-efficient, Laboratory test, Phasor data concentrators, Real-time simulator, Research efforts, Synchrophasors, Test platforms, Wide-area monitoring and controls
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-107199DOI: 10.1109/PESMG.2013.6672308ISI: 000331874300215Scopus ID: 2-s2.0-84893173930ISBN: 978-147991303-9 (tryckt)OAI: oai:DiVA.org:kth-107199DiVA, id: diva2:575239
Konferanse
2013 IEEE Power and Energy Society General Meeting, PES 2013; Vancouver, BC; Canada; 21 July 2013 through 25 July 2013
Forskningsfinansiär
Vinnova
Merknad

QC 20131015

Tilgjengelig fra: 2012-12-07 Laget: 2012-12-07 Sist oppdatert: 2014-04-10bibliografisk kontrollert
Inngår i avhandling
1. Data Quality in Wide-Area Monitoring and Control Systems: PMU Data Latency, Completness, and Design of Wide-Area Damping Systems
Åpne denne publikasjonen i ny fane eller vindu >>Data Quality in Wide-Area Monitoring and Control Systems: PMU Data Latency, Completness, and Design of Wide-Area Damping Systems
2013 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

The strain on modern electrical power system operation has led to an ever increasing utilization of new Information Communication Technology (ICT) systems to enhance the reliability and efficiency of grid operation. Among these proposals, Phasor Measurement Unit (PMU)-based Wide-Area Monitoring and Control (WAMC) systems have been recognized as one of the enablers of “Smart Grid”, particularly at the transmission level, due to their capability to improve the real-time situational awareness of the grid. These systems differ from the conventional Supervisory Control And Data Acquisition (SCADA) systems in that they provide globally synchronized measurements at high resolutions. On the other hand, the WAMC systems also impose several stringent requirements on the underlying ICT systems, including performance, security, and availability, etc. As a result, the functionality of the WAMC applications is heavily, but not exclusively, dependent on the capabilities of the underlying ICT systems. This tight coupling makes it difficult to fully exploit the benefits of the synchrophasor technology without the proper design and configuration of ICT systems to support the WAMC applications. The strain on modern electrical power system operation has led to an ever increasing utilization of new Information Communication Technology (ICT) systems to enhance the reliability and efficiency of grid operation. Among these proposals, Phasor Measurement Unit (PMU)-based Wide-Area Monitoring and Control (WAMC) systems have been recognized as one of the enablers of “Smart Grid”, particularly at the transmission level, due to their capability to improve the real-time situational awareness of the grid. These systems differ from the conventional Supervisory Control And Data Acquisition (SCADA) systems in that they provide globally synchronized measurements at high resolutions. On the other hand, the WAMC systems also impose several stringent requirements on the underlying ICT systems, including performance, security, and availability, etc. As a result, the functionality of the WAMC applications is heavily, but not exclusively, dependent on the capabilities of the underlying ICT systems. This tight coupling makes it difficult to fully exploit the benefits of the synchrophasor technology without the proper design and configuration of ICT systems to support the WAMC applications.

In response to the above challenges, this thesis addresses the dependence of WAMC applications on the underlying ICT systems. Specifically, two of the WAMC system data quality attributes, latency and completeness, are examined together with their effects on a typical WAMC application, PMU-based wide-area damping systems. The outcomes of this research include quantified results in the form of PMU communication delays and data frame losses, and probability distributions that can model the PMU communication delays. Moreover, design requirements are determined for the wide-area damping systems, and three different delay-robust designs for this WAMC application are validated based on the above results. Finally, a virtual PMU is developed to perform power system and communication network co-simulations.

The results reported by this thesis offer a prospect for better predictions of the performance of the supporting ICT systems in terms of PMU data latency and completeness. These results can be further used to design and optimize the WAMC applications and their underlying ICT systems in an integrated manner. This thesis also contributes a systematic approach to design the wide-area damping system considering the PMU data latency and completeness. Finally, the developed virtual PMU, as part of a co-simulation platform, provides a means to investigate the dependence of WAMC applications on the capabilities of the underlying ICT systems in a cost-efficient manner.

sted, utgiver, år, opplag, sider
Stockholm: KTH Royal Institute of Technology, 2013. s. xii, 47
Serie
Trita-EE, ISSN 1653-5146 ; 2013:038
Emneord
Phasor Measurement Units, Wide-Area Monitoring and Control systems, latency, completeness, power system communication, simulation, empirical study
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-129078 (URN)978-91-7501-886-7 (ISBN)
Disputas
2013-11-08, Sal F3, Lindstedtsvägen 26, KTH, Stockholm, 11:17 (engelsk)
Opponent
Veileder
Merknad

QC 20131015

Tilgjengelig fra: 2013-10-15 Laget: 2013-09-19 Sist oppdatert: 2013-10-15bibliografisk kontrollert

Open Access i DiVA

fulltext(1941 kB)425 nedlastinger
Filinformasjon
Fil FULLTEXT03.pdfFilstørrelse 1941 kBChecksum SHA-512
5f438d91ae8f953d34b2e260af048d591adff498b3726b1eccb0c2253ef0b0c200b9683c01bf090111037d8c27cbb95ff47ba0f93fba4d4dace2e9a213276261
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopusIEEEXplore

Personposter BETA

Zhu, KunHoneth, NicholasBabazadeh, DavoodLars, Nordström

Søk i DiVA

Av forfatter/redaktør
Zhu, KunDeo, SamarthHoneth, NicholasChenine, MoustafaBabazadeh, DavoodLars, Nordström
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 425 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 606 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf