Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A Platform for Wide Area Monitoring and Control System ICT Analysis and Development
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.ORCID-id: 0000-0003-3946-7655
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.ORCID-id: 0000-0003-3014-5609
Vise andre og tillknytning
2013 (engelsk)Inngår i: 2013 IEEE Grenoble Conference PowerTech, POWERTECH 2013, IEEE , 2013Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

PMU-based Wide Area Monitoring and Control(WAMC) system is introduced to improve the monitoring ofpower grid across large geographic areas and control the gridusing more efficient and smart applications. The performance ofWAMC applications in real power system scenarios and impactof their supporting Information and Communication Technology(ICT) on the data quality can be quantified and analyzed bypseudo-real co-simulation test beds. The purpose of this study isto propose and develop a WAMC testing platform to facilitate thereal-time simulation of dynamic power grid, the ICTinfrastructure that overlays the grid and WAMS applications.The platform consists of OPNET, a powerful communicationnetwork emulator, connected to a real-time power systemsimulator through virtualized PMU device. The end pointstations such as Phasor Data Concentrator or PMU-basedapplications are also linked to the platform through OPNET’sreal-simulation gateway called SITL (System-In-The-Loop). Toassess the performance of the platform architecture, a case studyhas been performed with five PMUs which collect the data from apower model and deliver to PMU-based mode-estimationapplication over a typical communication network. In this study,the results explicitly intend to quantify the effect of networkprotocols on data delay.

sted, utgiver, år, opplag, sider
IEEE , 2013.
Emneord [en]
Communication Network Emulator, Co-Simulation, PMU, System-In-The-Loop, Wide Area Monitoring and Control System, Opal-RT
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-109446DOI: 10.1109/PTC.2013.6652202Scopus ID: 2-s2.0-84890888328ISBN: 978-146735669-5 (tryckt)OAI: oai:DiVA.org:kth-109446DiVA, id: diva2:582180
Konferanse
2013 IEEE Grenoble Conference PowerTech, POWERTECH 2013; Grenoble, France, 16-20 June 2013
Forskningsfinansiär
StandUp
Merknad

QC 20140114

Tilgjengelig fra: 2013-01-03 Laget: 2013-01-03 Sist oppdatert: 2016-04-19bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Babazadeh, DavoodNordström, Lars

Søk i DiVA

Av forfatter/redaktør
Babazadeh, DavoodChenine, MoustafaZhu, KunNordström, LarsAl-Hammouri, Ahmad
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 640 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf