ICT system performance impact on wide area monitoring and control systems
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.ORCID-id: 0000-0003-4386-3781
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.
KTH, Skolan för elektro- och systemteknik (EES), Industriella informations- och styrsystem.ORCID-id: 0000-0003-3014-5609
2012 (engelsk)Inngår i: 44th International Conference on Large High Voltage Electric Systems 2012, 2012, s. 1-10Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Timely and accurate data with high resolutions holds great promise for more responsible and advanced power grid operations. The research has been focusing on design of monitoring and control scheme given assumptions that the supporting Information and Communication Technology (ICT) systems are capable to provide data and perform control with sufficient quality. A relatively less addressed aspect is the dependency of Wide area monitoring and control (WAMC) systems on their supporting ICT architecture which is usually a compromise between various concerns, such as data quality, interoperability or security. Without an appropriate ICT architecture design, the projected WAMC system functionalities run the risk of being jeopardized. This paper begins with a presentation about possible delays brought by complex data transfer and processing processes. Analytical experiments are conducted with purposes to quantify the maximum delay and input signal's sensitivity towards delay on a typical WAMC application where the control of Static Var Compensation (SVC) is coordinated with generator excitations using phasor measurements. Given the characteristics of this particular control scheme, two possible ICT architectures that provide data with different qualities are compared concerning the reliability of this WAMC application. The paper is concluded by proposing a generic ICT architectures enabling efficient WAMC systems implementation in terms of data quality.

sted, utgiver, år, opplag, sider
2012. s. 1-10
Emneord [en]
Communication delay, Data lose, ICT system, Performance, Wide area monitoring and control systems
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-116844Scopus ID: 2-s2.0-84872114313OAI: oai:DiVA.org:kth-116844DiVA, id: diva2:601274
Konferanse
44th International Conference on Large High Voltage Electric Systems 2012, 26 August 2012 through 31 August 2012, Paris
Merknad

QC 20130129

Tilgjengelig fra: 2013-01-29 Laget: 2013-01-28 Sist oppdatert: 2013-10-15bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Scopus

Personposter BETA

Zhu, KunNordström, Lars

Søk i DiVA

Av forfatter/redaktør
Zhu, KunChenine, MoustafaNordström, Lars
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 75 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf