Robustness study of the different immittance spectra and frequency ranges in bioimpedance spectroscopy analysis for assessment of total body composition
KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.ORCID-id: 0000-0002-6995-967X
Visa övriga samt affilieringar
2014 (Engelska)Ingår i: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 35, nr 7, s. 1373-1395Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The estimation of body fluids is a useful and common practice for assessment of disease status and therapy outcomes. Electrical bioimpedance spectroscopy (EBIS) methods are noninvasive, inexpensive and efficient alternatives for determination of body fluids. One of the main source of errors in EBIS measurements in the estimation of body fluids is capacitive coupling. In this paper an analysis of capacitive coupling in EBIS measurements was performed and the robustness of the different immittance spectra against it tested. On simulations the conductance (G) spectrum presented the smallest overall error, among all immittance spectra, in the estimation of the impedance parameters used to estimate body fluids. Afterwards the frequency range of 10-500 kHz showed to be the most robust band of the G spectrum. The accuracy of body fluid estimations from the resulting parameters that utilized G spectrum and parameters provided by the measuring device were tested on EBIS clinical measurements from growth hormone replacement therapy patients against estimations performed with dilution methods. Regarding extracellular fluid, the correlation between each EBIS method and dilution was 0.93 with limits of agreement of 1.06 +/- 2.95 l for the device, 1.10 +/- 2.94 l for G [10-500 kHz] and 1.04 +/- 2.94 l for G [5-1000 kHz]. Regarding intracellular fluid, the correlation between dilution and the device was 0.91, same as for G [10-500 kHz] and 0.92 for G [5- 1000 kHz]. Limits of agreement were 0.12 +/- 4.46 l for the device, 0.09 +/- 4.45 for G [10- 500 kHz] and 0.04 +/- 4.58 for G [5-1000 kHz]. Such close results between the EBIS methods validate the proposed approach of using G spectrum for initial Cole characterization and posterior clinical estimation of body fluids status.

Ort, förlag, år, upplaga, sidor
2014. Vol. 35, nr 7, s. 1373-1395
Nyckelord [en]
bioimpedance, bioconductance, measurement artefacts, body composition
Nationell ämneskategori
Biofysik Fysiologi
Identifikatorer
URN: urn:nbn:se:kth:diva-148360DOI: 10.1088/0967-3334/35/7/1373ISI: 000338476000014Scopus ID: 2-s2.0-84902679525OAI: oai:DiVA.org:kth-148360DiVA, id: diva2:736442
Anmärkning

QC 20140806

Tillgänglig från: 2014-08-06 Skapad: 2014-08-05 Senast uppdaterad: 2018-01-11Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Seoane, Fernando

Sök vidare i DiVA

Av författaren/redaktören
Buendia, RubénSeoane, FernandoLindecrantz, Kaj
Av organisationen
Medicinska sensorer, signaler och system
I samma tidskrift
Physiological Measurement
BiofysikFysiologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 384 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf