Fully automated corneal endothelial morphometry of images captured by clinical specular microscopy
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Biomedicinsk fysik och röntgenfysik.
2009 (Engelska)Ingår i: Ophthalmic Technologies XIX, SPIE - International Society for Optical Engineering, 2009, s. 716315-Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

The corneal endothelium serves as the posterior barrier of the cornea. Factors such as clarity and refractive properties of the cornea are in direct relationship to the quality of the endothelium. The endothelial cell density is considered the most important morphological factor. Morphometry of the corneal endothelium is presently done by semi-automated analysis of pictures captured by a Clinical Specular Microscope (CSM). Because of the occasional need of operator involvement, this process can be tedious, having a negative impact on sampling size. This study was dedicated to the development of fully automated analysis of images of the corneal endothelium, captured by CSM, using Fourier analysis. Software was developed in the mathematical programming language Matlab. Pictures of the corneal endothelium, captured by CSM, were read into the analysis software. The software automatically performed digital enhancement of the images. The digitally enhanced images of the corneal endothelium were transformed, using the fast Fourier transform (FFT). Tools were developed and applied for identification and analysis of relevant characteristics of the Fourier transformed images. The data obtained from each Fourier transformed image was used to calculate the mean cell density of its corresponding corneal endothelium. The calculation was based on well known diffraction theory. Results in form of estimated cell density of the corneal endothelium were obtained, using fully automated analysis software on images captured by CSM. The cell density obtained by the fully automated analysis was compared to the cell density obtained from classical, semiautomated analysis and a relatively large correlation was found.

Ort, förlag, år, upplaga, sidor
SPIE - International Society for Optical Engineering, 2009. s. 716315-
Serie
Progress in Biomedical Optics and Imaging - Proceedings of SPIE, ISSN 1605-7422 ; 7163
Nyckelord [en]
Cornea, Endothelium, Fourier, Microscopy, Morphology, Morphometry
Nationell ämneskategori
Oftalmologi Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:kth:diva-153606DOI: 10.1117/12.816850ISI: 000284821000025Scopus ID: 2-s2.0-65549124508ISBN: 978-0-8194-7409-4 (tryckt)OAI: oai:DiVA.org:kth-153606DiVA, id: diva2:753037
Konferens
Ophthalmic Technologies XIX, 24 January 2009 through 26 January 2009, San Jose, CA, United States
Anmärkning

QC 20141007

Tillgänglig från: 2014-10-07 Skapad: 2014-10-06 Senast uppdaterad: 2014-10-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Manneberg, Göran
Av organisationen
Biomedicinsk fysik och röntgenfysik
OftalmologiRadiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 238 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf