Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
The impact of horizontal offset of the cornea during corneal specular microscopy
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Biomedicinsk fysik och röntgenfysik.
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Biomedicinsk fysik och röntgenfysik.
2008 (Engelska)Ingår i: Progr. Biomed. Opt. Imaging Proc. SPIE, 2008Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

We are developing automated morphometric analysis of the corneal endothelium. Here, the general impact of horizontal offset of the cornea on morphometry was examined. Errors due to perspective during imaging with a Clinical Specular Microscope (CSM) were analyzed considering semi automated analysis software and fully automated Fourier analysis software. Methods: A mathematical model of the cornea was created. Trigonometry was applied to find the relationship between the horizontal offset of the cornea relative to the microscope objective, and the consecutive errors from perspective changes in the image. An experimental setup was created using a cornea made of polymethyl methacrylate (PMMA). The posterior surface of the PMMA cornea was horizontally marked. The PMMA cornea was placed in a holder. Difference in refractive index between real endothelium and aqueous humor was emulated using high refractive index liquid. Images with varying horizontal offset on the PMMA corneal posterior surface, along with their relative offset coordinates were captured, using CSM. Results: Experiments using controlled offset of the cornea in relation to its center estimated that analyzable images can be acquired within an interval of 1.26 mm, using central cornea sampling CSM. Because of refractive indices along with light scattering differences between the corneal tissue and PMMA , the 1.26 mm interval should be considered a first estimate for feasible CSM images. The effect of corneal endothelial offset during imaging with CSM or fully automated Fourier analysis should be considered.

Ort, förlag, år, upplaga, sidor
2008.
Serie
Progress in Biomedical Optics and Imaging - Proceedings of SPIE, ISSN 1605-7422 ; 6844
Nyckelord [en]
Cornea, Endothelium, Fourier, Microscopy, Morphometrics, Offset, Computer software, Endothelial cells, Fourier analysis, Light scattering, Mathematical models, Polymethyl methacrylates, Corneal specular microscopy, Biological organs
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:kth:diva-154458DOI: 10.1117/12.779573ISI: 000254982000020Scopus ID: 2-s2.0-43949109291ISBN: 9780819470195 (tryckt)OAI: oai:DiVA.org:kth-154458DiVA, id: diva2:758313
Konferens
Ophthalmic Technologies XVIII, 19-21 January 2008, San Jose, CA, USA
Anmärkning

QC 20141027

Tillgänglig från: 2014-10-27 Skapad: 2014-10-20 Senast uppdaterad: 2014-10-27Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Bucht, CurryManneberg, Göran
Av organisationen
Biomedicinsk fysik och röntgenfysik
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 248 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf