Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Recording the diffraction pattern reflected from corneal endothelium
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Biomedicinsk fysik och röntgenfysik. Karolinska Institutet, Sweden.
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Biomedicinsk fysik och röntgenfysik.
2007 (engelsk)Inngår i: Ophthalmic Technologies XVII, SPIE - International Society for Optical Engineering, 2007, s. 42610-42610Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

As a part of an ongoing research project on morphometrical diagnosis of the corneal endothelium, an experimental optical setup has been created. The structure of the corneal endothelial cells could be considered a reflecting periodical aperture. Hence, the diffraction pattern reflected from the endothelium contains valuable morphometrical information. In the present work, focus has been on sampling the posterior surface of explanted corneas. Methods: An optical setup was created, using a 632.8 nm He-Ne laser as the light source. The desired diffraction pattern was produced as a collimated reflection. Hence, because the posterior surface of the cornea is concave, lenses were used to attain the right divergence of the light impingent on the corneal endothelium. These lenses also made it possible to adjust the sampling spot size. A beam splitter (BS) was used to provide an optical path for both the impinging laser beam as well as the reflected diffracted beam. The lens acting as a Fourier lens was then placed after the BS. At the back focal plane of the Fourier lens, a CCD detector was used for recording in the Fourier plane. In the process of creating the setup, explanted corneas were emulated using grated contact lenses. Results: The current optical set up allows identification of a diffraction pattern from a concave spherical surface with a radius of curvature of the same order as a human cornea.

sted, utgiver, år, opplag, sider
SPIE - International Society for Optical Engineering, 2007. s. 42610-42610
Serie
Progress in Biomedical Optics and Imaging - Proceedings of SPIE, ISSN 1605-7422 ; 6426
Emneord [en]
Cornea, Diffraction, Endothelium, Fourier, Morphometry
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-155591DOI: 10.1117/12.717478ISI: 000246519000023Scopus ID: 2-s2.0-34548208232ISBN: 0819465399 (tryckt)ISBN: 978-081946539-9 OAI: oai:DiVA.org:kth-155591DiVA, id: diva2:762071
Konferanse
Ophthalmic Technologies XVII, 20 January 2007 through 23 January 2007, San Jose, CA, United States
Merknad

QC 20141110

Tilgjengelig fra: 2014-11-10 Laget: 2014-11-07 Sist oppdatert: 2014-11-10bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Søk i DiVA

Av forfatter/redaktør
Bucht, CurryManneberg, Göran
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 177 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf