Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Improved confinement in JET high β plasmas with an ITER-like wall
Visa övriga samt affilieringar
2015 (Engelska)Ingår i: Nuclear Fusion, ISSN 0029-5515, E-ISSN 1741-4326, Vol. 55, nr 5, artikel-id 053031Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The replacement of the JET carbon wall (C-wall) by a Be/W ITER-like wall (ILW) has affected the plasma energy confinement. To investigate this, experiments have been performed with both the C-wall and ILW to vary the heating power over a wide range for plasmas with different shapes. It was found that the power degradation of thermal energy confinement was weak with the ILW; much weaker than the IPB98(y,2) scaling and resulting in an increase in normalized confinement from H<inf>98</inf> ∼ 0.9 at β<inf>N</inf> ∼ 1.5 to H<inf>98</inf> ∼ 1.2-1.3 at β<inf>N</inf> ∼ 2.5 - 3.0 as the power was increased (where H<inf>98</inf> = τ<inf>E</inf>/τ<inf>IPB98(y,2)</inf> and β<inf>N</inf> = β<inf>T</inf>B<inf>T</inf>/aI<inf>P</inf> in % T/mMA). This reproduces the general trend in JET of higher normalized confinement in the so-called 'hybrid' domain, where normalized β is typically above 2.5, compared with 'baseline' ELMy H-mode plasmas with β<inf>N</inf> ∼ 1.5 - 2.0. This weak power degradation of confinement, which was also seen with the C-wall experiments at low triangularity, is due to both increased edge pedestal pressure and core pressure peaking at high power. By contrast, the high triangularity C-wall plasmas exhibited elevated H<inf>98</inf> over a wide power range with strong, IPB98(y,2)-like, power degradation. This strong power degradation of confinement appears to be linked to an increase in the source of neutral particles from the wall as the power increased, an effect that was not reproduced with the ILW. The reason for the loss of improved confinement domain at low power with the ILW is yet to be clarified, but contributing factors may include changes in the rate of gas injection, wall recycling, plasma composition and radiation. The results presented in this paper show that the choice of wall materials can strongly affect plasma performance, even changing confinement scalings that are relied upon for extrapolation to future devices.

Ort, förlag, år, upplaga, sidor
2015. Vol. 55, nr 5, artikel-id 053031
Nyckelord [en]
neutral particles, plasma confinement, power degradation, wall materials
Nationell ämneskategori
Fysik
Identifikatorer
URN: urn:nbn:se:kth:diva-166940DOI: 10.1088/0029-5515/55/5/053031ISI: 000353546700032Scopus ID: 2-s2.0-84928667412OAI: oai:DiVA.org:kth-166940DiVA, id: diva2:818514
Anmärkning

QC 20150609

Tillgänglig från: 2015-06-09 Skapad: 2015-05-21 Senast uppdaterad: 2017-12-04Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Frassinetti, Lorenzo

Sök vidare i DiVA

Av författaren/redaktören
Frassinetti, Lorenzo
Av organisationen
Fusionsplasmafysik
I samma tidskrift
Nuclear Fusion
Fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 56 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf