NanoXCT: Development of a laboratory nano-CT system
Vise andre og tillknytning
2014 (engelsk)Inngår i: Proceedings of SPIE - The International Society for Optical Engineering, 2014Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

The NanoXCT project aims at developing a laboratory nano-CT system for non-destructive testing applications in the micro- and nano-technology sector. The system concept omits the use of X-ray optics, to be able to provide up to 1 mm FOV (at 285 nm voxel size) and down to 50 nm voxel size (at 0.175 mm FOV) while preserving the flexibility of state-of-the-art micro-CT systems. Within the project a suitable X-ray source, detector and manipulation system are being developed. To cover the demand for elemental analysis, the project will additionally include X-ray spectroscopic techniques. These will be reported elsewhere while this paper is focused on the imaging part of the project. We introduce the system concept including design goals and constraints, and the individual components. We present the current state of the prototype development including first results.

sted, utgiver, år, opplag, sider
2014.
Emneord [en]
Computed tomography, Nano-CT, Nano-focus, NanoXCT, Photon-counting X-ray detector, Timepix detector, Transmission tube, Imaging systems, Nondestructive examination, Spectroscopic analysis, Tomography, X ray apparatus, X ray spectroscopy, Timepix detectors, X-ray detector, Computerized tomography
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-167861DOI: 10.1117/12.2061752ISI: 000344554400017Scopus ID: 2-s2.0-84923031242ISBN: 9781628412390 (tryckt)OAI: oai:DiVA.org:kth-167861DiVA, id: diva2:820768
Konferanse
Developments in X-Ray Tomography IX, 18 August 2014 through 20 August 2014
Merknad

QC 20150612

Tilgjengelig fra: 2015-06-12 Laget: 2015-05-22 Sist oppdatert: 2016-11-28bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Larsson, DanielHolmberg, Anders

Søk i DiVA

Av forfatter/redaktør
Larsson, DanielHolmberg, Anders
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 145 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf