  • asciidoc
  • rtf
Non-destructive condition monitoring of aged ethylene-propylene copolymer cable insulation samples using dielectric spectroscopy and NMR spectroscopy
KTH, Skolan för kemivetenskap (CHE), Fiber- och polymerteknologi.
KTH, Skolan för kemivetenskap (CHE), Fiber- och polymerteknologi.ORCID-id: 0000-0003-3049-7225
Vise andre og tillknytning
2015 (engelsk)Inngår i: Polymer testing, ISSN 0142-9418, E-ISSN 1873-2348, Vol. 46, s. 72-78Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The causes of changes in dielectric response as a result of thermal and irradiative ageing of cable insulation of ethylene propylene copolymer rubber containing 38 wt.% filler were investigated. Samples were aged in three different combinations of irradiation dose rate and temperature, 0.42 kGy h(-1) at 85 degrees C, and 1.58 kGy h(-1) at 55 and 85 degrees C, and subsequently studied by dielectric spectroscopy, NMR spectroscopy using a portable spectrometer, and tensile testing. The extractable mass fraction and density were determined and related to the imaginary part of the dielectric permittivity at 100 kHz. The ageing led to an increase in the dielectric permittivity, stiffness, density and degree of oxidation, together with a decrease in both strain-at-break and relaxation time, as revealed by NMR spectroscopy. Except for the strain-at-break, the properties changed in a linear fashion with increasing imaginary part of the dielectric permittivity at 100 kHz, with particularly good agreement with respect to the density. As these properties are affected by the degree of oxidation, the results show that both NMR using a portable spectrometer and dielectric spectroscopy can be used as condition monitoring techniques to detect the degree of oxidation in complex systems such as filled copolymers.

sted, utgiver, år, opplag, sider
Elsevier, 2015. Vol. 46, s. 72-78
Emneord [en]
Ethylene propylene rubber, Radiation ageing, Thermal ageing, Dielectric response, Portable NMR spectrometer, Condition monitoring
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-174932DOI: 10.1016/j.polymertesting.2015.07.002ISI: 000361160100012Scopus ID: 2-s2.0-84937207340OAI: oai:DiVA.org:kth-174932DiVA, id: diva2:861860
Forskningsfinansiär
Swedish Radiation Safety Authority, SSM 202-593
Merknad

QC 20151019

Tilgjengelig fra: 2015-10-19 Laget: 2015-10-09 Sist oppdatert: 2017-12-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Pourmand, P.

Søk i DiVA

Av forfatter/redaktør
Linde, E.Pourmand, P.Gedde, U. W.
Av organisasjonen
I samme tidsskrift
Polymer testing

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 69 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf