Slightly superior performance of bioimpedance spectroscopy over single frequency regression equations for assessment of total body water
KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system. University of Boras, Sweden.ORCID-id: 0000-0002-6995-967X
KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system. Karolinska Institute, Sweden.ORCID-id: 0000-0001-7807-8682
Visa övriga samt affilieringar
2015 (Engelska)Ingår i: Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE, IEEE conference proceedings, 2015, s. 3707-3710Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Electrical bioimpedance has been used for several decades to assess body fluid distribution and body composition by using single frequency and bioimpedance spectroscopic (BIS) techniques. It remains uncertain whether BIS methods have better performance compare to single frequency regression equations. In this work the performance of two BIS methods and four different 50 kHz single frequency prediction equations was studied in a data set of wrist-to-ankle tetrapolar BIS measurements (5-1000 kHz) together with reference values of total body water obtained by tritium dilution in 92 patients. Data were compared using regression techniques and BlandAltman plots. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Limits of agreement analysis indicated that the population level performance of Sun’s prediction equations was very similar to the performance of both BIS methods. However, BIS methods in practice have slightly better predictive performance than the single-frequency equations as judged by higher correlation and the limits of agreement from the Bland-Altman analysis. In any case, the authors believe that an accurate evaluation of performance of the methods cannot be done as long as the evaluation is done using Bland-Altman analysis, the commonly accepted technique for this kind of performance comparisons.

Ort, förlag, år, upplaga, sidor
IEEE conference proceedings, 2015. s. 3707-3710
Serie
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, ISSN 1557-170X ; 7319198
Nyckelord [en]
Atmospheric measurements, Bioimpedance, Correlation, Frequency measurement, Impedance, Impedance measurement, Mathematical model
Nationell ämneskategori
Annan medicinteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-177121DOI: 10.1109/EMBC.2015.7319198ISI: 000371717203245Scopus ID: 2-s2.0-84953220227ISBN: 978-1-4244-9270-1 (tryckt)OAI: oai:DiVA.org:kth-177121DiVA, id: diva2:874527
Konferens
Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE, Milan, Italy
Anmärkning

QC 20160127

Tillgänglig från: 2015-11-27 Skapad: 2015-11-15 Senast uppdaterad: 2016-04-21Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopushttp://dx.doi.org/10.1109/EMBC.2015.7319198

Personposter BETA

Seoane, FernandoAbtahi, Farhad

Sök vidare i DiVA

Av författaren/redaktören
Seoane, FernandoAbtahi, Farhad
Av organisationen
Medicinska sensorer, signaler och system
Annan medicinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 214 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf