Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Prediction of residual stresses in cross-linked polyethylene cable insulation
KTH, School of Engineering Sciences (SCI), Solid Mechanics (Dept.).
KTH, School of Engineering Sciences (SCI), Solid Mechanics (Dept.).ORCID iD: 0000-0002-0307-8917
2005 (English)In: Polymer Engineering and Science, ISSN 0032-3888, E-ISSN 1548-2634, Vol. 45, no 8, 1132-1139 p.Article in journal (Refereed) Published
Abstract [en]

Modeling of the manufacturing process of high-voltage power cables was performed with the aim of predicting residual stresses in the cable insulation. A viscoelastic power law-type constitutive model was used which incorporates temperature and crystallinity dependence of the parameters. In this way the mechanical problem is coupled to the heat transfer and crystallization problems. In order to illustrate the effects of relaxation, a comparison to a thermoelastic material model is made.

Place, publisher, year, edition, pages
2005. Vol. 45, no 8, 1132-1139 p.
Keyword [en]
Chemical relaxation, Crosslinking, Crystallization, Electric cables, Electric insulation, Electric potential, Heat transfer, Residual stresses, Thermoelasticity, Viscoelasticity
National Category
Other Materials Engineering
Identifiers
URN: urn:nbn:se:kth:diva-5894DOI: 10.1002/pen.20376ISI: 000231037600011Scopus ID: 2-s2.0-25144496441OAI: oai:DiVA.org:kth-5894DiVA: diva2:10423
Note
QC 20100914Available from: 2006-06-01 Created: 2006-06-01 Last updated: 2010-09-14Bibliographically approved
In thesis
1. Residual Stresses and Strains in Cross-linked Polyethylene Power Cable Insulation
Open this publication in new window or tab >>Residual Stresses and Strains in Cross-linked Polyethylene Power Cable Insulation
2006 (English)Doctoral thesis, comprehensive summary (Other scientific)
Abstract [en]

The subject of this thesis is modeling of the manufacturing process of high voltage power cables with the aim of predicting residual stresses and strains in the cable insulation. The studied material is cross-linked polyethylene (XLPE), which at room temperature is a semi-crystalline viscoelastic solid. Above the crystallization temperature the material exhibits a rubber type behavior due to the crosslinks.

An extensive set of uniaxial tensile relaxation tests were used for the mechanical characterization of XLPE. These experiments were complemented by pressure volume temperature experiments as well as density and crystallinity measurements. Based on the experiments, initially a linear and later a non-linear viscoelastic power law model was formulated, incorporating temperature and crystallinity dependence. The non-linear model is based on the Schapery formulation. Evaluations of the model were performed with additional uniaxial experiments. These included comparisons between predicted stress responses and measured values during relaxation tests with transient temperature histories, during two step relaxation experiments and during uniaxial tests with constant strain rate loading.

The initial modeling work focused on the prediction of residual stresses which develop during the cooling stage of the manufacturing process. As the constitutive model incorporates temperature and crystallinity dependence, the mechanical problem is coupled to the heat transfer and crystallization problems. Calculations were performed for a vertical manufacturing line. The effects of a viscoelastic material model are illustrated by a comparison to a stress state predicted by a thermo-elastic material model.

A final study concerns the modeling of the residual strains in the insulation. It was found that strains originating at cross-linking of the molecules play a signifi- cant role for buildup of residual strains. Calculations are performed for the same vertical process line as before. Good agreement was found between predicted and experimentally obtained residual strains. Based on the residual strain state an estimate is made for the upper limit of shrink-back of the cable insulation.

Place, publisher, year, edition, pages
Stockholm: KTH, 2006. viii, 23 p.
Series
Trita-HFL. Report / Royal Institute of Technology, Solid mechanics, ISSN 1654-1472 ; 0412
National Category
Other Materials Engineering
Identifiers
urn:nbn:se:kth:diva-4020 (URN)
Public defence
2006-06-13, Sal F3, Lindstedtsvägen 26, Stockholm, 10:15
Opponent
Supervisors
Note

QC 20100915

Available from: 2006-06-01 Created: 2006-06-01 Last updated: 2013-01-14Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopushttp://www3.interscience.wiley.com/cgi-bin/abstract/110549028/ABSTRACT

Authority records BETA

Gudmundson, Peter

Search in DiVA

By author/editor
Olasz, LorantGudmundson, Peter
By organisation
Solid Mechanics (Dept.)
In the same journal
Polymer Engineering and Science
Other Materials Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 620 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf