Change search
ReferencesLink to record
Permanent link

Direct link
Interpreting and Implementing IEC 61850-90-5 Routed-Sampled Value and Routed-GOOSE Protocols for IEEE C37.118.2 Compliant Wide-Area Synchrophasor Data Transfer
KTH, School of Electrical Engineering (EES), Electric power and energy systems. SmarTS Lab.ORCID iD: 0000-0001-9677-0832
KTH, School of Electrical Engineering (EES), Electric power and energy systems. SmarTS Lab.ORCID iD: 0000-0002-4125-1055
Catalonia Institute for Energy Research (IREC), Barcelona, Spain.
KTH, School of Electrical Engineering (EES), Electric power and energy systems. SmarTS Lab.ORCID iD: 0000-0002-6090-1674
Show others and affiliations
2016 (English)In: Electric power systems research, ISSN 0378-7796, E-ISSN 1873-2046Article in journal (Refereed) Accepted
Abstract [en]

Flexibility and adaptability requirements of future electric power grids for integrating DERs call for the developmentof Wide-Area Monitoring, Protection And Control (WAMPAC) applications, utilizing synchrophasor measurementsprovided by the Phasor Measurement Units (PMUs).IEEE C37.118 is the most utilized protocol for real-time exchange of synchronized phasor measurement data. In orderto full some gaps not addressed in IEEE C37.118, and also to harmonize with the IEC 61850 power utility automationstandard, the IEC 61850-90-5 technical report has been developed. IEC TR 61850-90-5 introduces a mechanism fortransfer of digital states and time synchronized phasor measurement data over wide-area networks between PhasorMeasurement Units (PMUs), Phasor Data Concentrators (PDCs) and WAMPAC applications in the context of IEC61850.This work interprets the IEEE C37.118.2 and IEC 61850-90-5 Routed-Sampled Value and Routed-GOOSE protocolsand describes the design and implementation of a library named Khorjin with the functionality of (1) an IEEE C37.118.2to IEC 61850-90-5 gateway and protocol converter and, (2) an IEC 61850-90-5 subscriber and trac parser.The main contribution of this work is the development of Khorjin library using only standard C libraries (i.e.independent from any operating system). This is allowing the use of the library in dierent platforms.The design requirements and functionality of the Khorjin library has been tested in the KTH SmarTS Lab Real-TimeHardware-in-the-Loop (HIL) simulation environment to assess its conformance to the functional requirements of IEEEC37.118.2 and IEC 61850-90-5 standards.

Place, publisher, year, edition, pages
Elsevier, 2016.
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-197667OAI: oai:DiVA.org:kth-197667DiVA: diva2:1052501
Projects
FP7 IDE4L
Funder
StandUp
Available from: 2016-12-06 Created: 2016-12-06 Last updated: 2016-12-27

Open Access in DiVA

No full text

Search in DiVA

By author/editor
Seyed Reza, FirouziVanfretti, LuigiHooshyar, HosseinMahmood, Farhan
By organisation
Electric power and energy systems
In the same journal
Electric power systems research
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

Total: 75 hits
ReferencesLink to record
Permanent link

Direct link