Dielectric response measurement by impulse stimulus on AC: Measurement considerations, and laboratory testing on a bushing
KTH, School of Electrical Engineering (EES), Electromagnetic Engineering.
KTH, School of Electrical Engineering (EES), Electromagnetic Engineering.
KTH, School of Electrical Engineering (EES), Electromagnetic Engineering.
2017 (English)In: IEEE transactions on dielectrics and electrical insulation, ISSN 1070-9878, E-ISSN 1558-4135, Vol. 24, no 1, 511-518 p., 7873509Article in journal (Refereed) Published
Abstract [en]

Dielectric response (DR) measurement is commonly used for condition assessment of insulation systems of power components. A method for measurement of dielectric response using the stimulus of natural transients such as lightning and switching impulses was proposed in earlier work. Its desirable features include the ability to make measurements online over a range of frequencies, without requiring a voltage source. This article presents a laboratory demonstration of the method on a 150 kV service-aged transformer bushing, where the stimulus was a standard lightning impulse voltage superimposed on an AC voltage. Several aspects of the measurement and data processing that affect the results are studied experimentally and numerically. The results are compared with low-voltage frequency domain spectroscopy (FDS). Reasonable accuracy for monitoring changes in DR can be achieved by suitable choice of measurement circuit and data acquisition. The study suggests an approach for online monitoring of dielectric properties of power transformer bushings, and diagnostics of defects that affect the high frequency region of DR, such as moisture content.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE), 2017. Vol. 24, no 1, 511-518 p., 7873509
Keyword [en]
bushing, condition monitoring, Dielectric response, high voltage impulse, loss tangent, online, transient
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-208150DOI: 10.1109/TDEI.2016.006084ISI: 000396400600057ScopusID: 2-s2.0-85015742530OAI: oai:DiVA.org:kth-208150DiVA: diva2:1104362
Funder
SweGRIDS - Swedish Centre for Smart Grids and Energy StorageSwedish Energy Agency
Note

QC 20170601

Available from: 2017-06-01 Created: 2017-06-01 Last updated: 2017-06-01Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Nikjoo, RoyaTaylor, NathanielEdin, Hans
By organisation
Electromagnetic Engineering
In the same journal
IEEE transactions on dielectrics and electrical insulation
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 25 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf