Analys av kondensatorbatteriers tillkopplingsfenomen: Undersökning av de kopplingsfenomen som uppstår vid tillkoppling av kondensatorbatterier och deras påverkan på närliggande komponenter
KTH, School of Technology and Health (STH), Medical Engineering, Computer and Electronic Engineering.
KTH, School of Technology and Health (STH), Medical Engineering, Computer and Electronic Engineering.
2017 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
Analysis of capacitor banks switching phenomena : Investigation of switching phenomena that occurs due to capacitor banks switching and their effects on surrounding components (English)
Abstract [sv]

Många elektriska apparater är i behov av reaktiv effekt för att kunna fungera. Transport av reaktiv effekt tar onödig plats av den tillgängliga kapaciteten i elnätet, därför används kondensatorbatterier nära slutanvändaren för att generera reaktiv effekt. Därmed genereras och förbrukas den reaktiva effekten i en avskild del av nätet. Tillkoppling av kondensatorbatterier ger upphov till transienter som kan skada andra närliggande komponenter.

Utifrån det verkliga ställverket Stallbacka i Trollhättan har denna rapport analyserat de transienter som uppstår efter tillkoppling av ett kondensatorbatteri inom mellanspänningsområdet. Analysen har innefattat hur stora transienterna blir efter olika förutsättningar och scenarier. Resultatet visade att transienterna i detta fall aldrig nådde upp till några allvarliga nivåer, och därmed klarade komponenterna sig med god marginal. Huruvida transienterna påverkar elkvaliteten är oklart, då det inte finns några definierade krav.

Slutligen skulle ett beräkningsverktyg för förutspådda transienter tas fram. Beräkningsverktyget blev aldrig fullständigt på grund av den ohanterliga lösningen som erhölls.

Abstract [en]

Many electrical devices need reactive power to operate. Transmission of reactive power occupies a proportion of the available capacity in the power system and therefore capacitor banks are used near to the end user to generate reactive power. Thus, the reactive effect is generated and consumed in a separate part of the power system. Capacitor banks switching causes transients which may damage the surrounding components.

Based on the real substation Stallbacka in Trollhättan, this study has analysed capacitor banks switching transients within the medium voltage level. The analysis has covered the size of these transients according to different conditions and scenarios. The result showed that the transients in this case never reached serious levels, thus there was no impact on the components. It is not clear whether the transients affect the power quality because there are no defined limits. 

A calculation tool to the predicted transients was supposed to be created in the process. This calculation tool was never completed due to the unmanageable solution that was obtained.

Place, publisher, year, edition, pages
2017. , p. 68
Series
TRITA-STH ; 2017:46
Keywords [en]
Transient, overvoltage, overcurrent, switching phenomenon, capacitor bank, vacuum circuit breaker, medium voltage level, power quality
Keywords [sv]
Transient, överspänning, överström, tillkopplingsfenomen, kondensatorbatteri, vakuumbrytare, mellanspänningsområde, elkvalitet
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-208948OAI: oai:DiVA.org:kth-208948DiVA, id: diva2:1109133
External cooperation
Siemens AB
Subject / course
Electrical Engineering
Educational program
Bachelor of Science in Engineering - Electrical Engineering
Supervisors
Examiners
Available from: 2017-06-16 Created: 2017-06-13 Last updated: 2018-11-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Computer and Electronic Engineering
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 296 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf