Resolution improvement in x-ray imaging with an energy-resolving detector
KTH, School of Engineering Sciences (SCI), Physics, Physics of Medical Imaging.
KTH, School of Engineering Sciences (SCI), Physics, Physics of Medical Imaging.
2017 (English)In: Medical Imaging 2017: Physics of Medical Imaging, SPIE - International Society for Optical Engineering, 2017, Vol. 10132, 101321DConference paper, (Refereed)
Abstract [en]

In x-ray imaging, improving spatial resolution is an important goal, but developing detectors with smaller pixels is technically challenging. We demonstrate a technique for improving the spatial resolution by utilizing the fact that linear attenuation coefficients of all substances within the human body can be expressed, to a good approximation, as a linear combination of two basis functions, or three if there is iodine contrast present in the image. When the x rays pass an interface parallel to the beam direction, the exponential attenuation law makes the linear attenuation coefficient measured by the detector a nonlinear combination of the linear attenuation coefficients on each side of the interface. This so-called nonlinear partial volume effect causes the spectral response to be dependent on the steepness of interfaces in the imaged volume. In this work, we show how this effect can be used to improve the spatial resolution in spectral projection x-ray imaging and quantify the achievable resolution improvement. We simulate x-ray transmission imaging of sharp and gradual changes in the projected path length of iodine contrast with an ideal energy-resolving photon-counting detector and demonstrate that the slope of the transition can be determined from the registered spectrum. We simulate piecewise-linear transitions and show that the algorithm is able to reproduce the transition profile on a subpixel scale. The FWHM resolution of the method is 5-30 % of the pixel width. The results show that an energy-resolving detector can be used to improve spatial resolution when imaging interfaces of highly attenuating objects.

Place, publisher, year, edition, pages
SPIE - International Society for Optical Engineering, 2017. Vol. 10132, 101321D
Series
Progress in Biomedical Optics and Imaging - Proceedings of SPIE, ISSN 1605-7422 ; 10132
Keyword [en]
Nonlinear partial volume effect, Photon-counting, Spatial resolution, Spectral imaging, Super-resolution
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:kth:diva-210001DOI: 10.1117/12.2254572Scopus ID: 2-s2.0-85020454284ISBN: 9781510607095 (print)OAI: oai:DiVA.org:kth-210001DiVA: diva2:1116850
Conference
Medical Imaging 2017: Physics of Medical Imaging, Orlando, United States, 13 February 2017 through 16 February 2017
Note

QC 20170628

Available from: 2017-06-28 Created: 2017-06-28 Last updated: 2017-06-28Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Persson, MatsDanielsson, Mats
By organisation
Physics of Medical Imaging
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 1 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf