Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Standardmätning samt direktivitetsanalys för luftrenaren Blueair Pro M
KTH, School of Engineering Sciences (SCI).
KTH, School of Engineering Sciences (SCI).
2017 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Sound power and directivity measurement for air cleaner (English)
Abstract [sv]

Uppgiften i denna rapport avser att svara på frågan hur direktiviteten och hur den A-vägda ljudtrycksnivån ser ut kring luftrenaren Pro M, från företaget Blueair, när den körs på tre olika förinställda fläkthastigheter och enligt internationell standard ISO3744. Inom ramen för projektet fanns det även en önskan att få en uppfattning om hur direktiviteten och den totala A-vägda ljudtrycksnivån såg ut om man ställde luftrenaren invid en vägg. Detta utfördes med egna antaganden om vilka mätpunkter som kan vara intressanta och är därmed inte direkt tagen från någon standard. Mätningarna har gjorts i det semi eko-fria mätrummet på MWL laboratoriet på Kungliga Tekniska Högskolan.

Resultaten för mätningarna inom ISO3744 visade ganska tydligt att skillnaden i ljudtrycksnivå mellan den lägsta och näst lägsta hastigheten inte var så stor, vilket innebar att maskinens två lägsta hastigheter ej togs i beaktning för extra mätningarna invid väggen. Mätningarna och analys enligt standard gav totala A-vägda ljudtrycksnivåer i medelvärde för maskinens tre olika varvtal. Dessa blev 38 dB(A), 38.6 dB(A) respektive 48.4 dB(A).

Ljudnivån i rummet mättes och analyserades då väggen befann sig på både maskinens kort och långsida. Jämförande resultat av dessa gav slutsatsen att ljudnivåerna i rummet blev lägre då placeringen av vägg var på maskinens kortsida med insug mot väggen. De maximala uppmätta och A-vägda ljudtrycksnivåerna för dessa fall var 47.2 dB(A) respektive 47.6 dB(A).

Direktivitetsanalys har utförts genom att i Matlab-plottar (3D meshes) visualisera skillnad i storlek för uppmätta värdena i de olika definierade mätpunkterna. Slutsatsen av denna analys var att ljudbilden koncentrerar sig mest på maskinens framsida (Maskinens utblås) vid låga höjder.

Abstract [en]

The assignment in this report is focused on giving answers to the question how the directivity and the A-weighted sound pressure level behaves around the air cleaner Pro M, from the company Blueair, when it runs on three different pre-installed fan speeds due to the international standard ISO3744. Within the project there was also a wish to get a perception of the directivity and how the A-weighted sound pressure levels behaves if the air cleaner is standing close to a wall. This was executed with own assumptions about the measurement points of interest and therefore it has not been taken directly from any international standard. The measurement has always been measured in the semi-anechoic-room at the MWL laboratory at Royal Institute of Technology.

The results from the measurements within the international standard ISO3744 showed that the difference between the sound pressure level for the lowest and second lowest speed was very small, which made up to the conclusion to not use the first and second lowest speeds for the measurements including the wall. Measurements and analysis according to standard gave total A-weighted averaged sound pressure levels for the three different speeds. These were 38 dB(A), 38.6 dB(A) and 48.4 dB(A) respectively.

The sound level in the room was measured and analyzed when the wall was included both on the air cleaner’s short side and long side. When these results were compared it was concluded that the sound pressure levels in the room was lower when the wall was positioned on the short side. The measured and A-weighted sound pressure levels for these two cases were 47.2 dB(A) and 37.6 dB(A) respectively.

The analyze for directivity was illustrated in Matlab plots (3D meshes) as difference in visual size for the measured values in each of the defined measurement coordinates. The conclusion for this analysis was that the sound for the air cleaner is concentrated on the front side (at the exhaust) and at low heights.

Place, publisher, year, edition, pages
2017. , p. 26
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-219452OAI: oai:DiVA.org:kth-219452DiVA, id: diva2:1163182
Supervisors
Examiners
Available from: 2017-12-06 Created: 2017-12-06 Last updated: 2017-12-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
School of Engineering Sciences (SCI)
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 6 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf