Influence of press films on conduction in polyethylene plaque samples
KTH, School of Electrical Engineering and Computer Science (EECS), Electromagnetic Engineering.ORCID iD: 0000-0003-1393-9511
2016 (English)In: Dielectrics (ICD), 2016 IEEE International Conference on, France: Institute of Electrical and Electronics Engineers (IEEE), 2016, article id 16250905Conference paper, Published paper (Refereed)
Abstract [en]

Press molded plaque samples are commonly used for characterization of polymeric insulation materials. Such samples are prepared by pressing polymer granulates sandwiched between two layers of protective press films at high temperatures and pressures. Polyethylene terephthalate (PET) film is a common press film since it tolerates high temperatures, acts as a good diffusion barrier and can be separated from the molded polyethylene sample easily. In this work, studies are performed on the influence of the pressing film on the dielectric properties of press molded polyethylene insulation samples. Volume resistivity is measured under high voltage DC at different conditions on samples pressed using different press films and different preparations. Furthermore, PEA measurements under high voltage DC is performed on plaque samples press molded with different press films. It is found that press molding using PET film leads to a considerably higher apparent conductivity of the samples in comparison to using aluminum foil. Choice of press film, also influences the space charge measurement results. It is concluded that the influence of the press film used during sample preparation cannot be neglected and this effect should be evaluated carefully in material characterization research. According to the results in this work, aluminum foil seems to be a better option as a press film in comparison to PET press film.

Place, publisher, year, edition, pages
France: Institute of Electrical and Electronics Engineers (IEEE), 2016. article id 16250905
Keywords [en]
HVDC insulation, power cable, polyethylene, conductivity, polyethylene terephthalate, space charge
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electrical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-228364DOI: 10.1109/ICD.2016.7547828Scopus ID: 2-s2.0-84988410105ISBN: 978-1-5090-2804-7 (electronic)OAI: oai:DiVA.org:kth-228364DiVA, id: diva2:1209377
Conference
Dielectrics (ICD), 2016 IEEE International Conference on
Note

QC 20180523

Available from: 2018-05-22 Created: 2018-05-22 Last updated: 2018-05-23Bibliographically approved
In thesis
1. Characterization of Conduction and Polarization Properties of HVDC Cable XLPE Insulation Materials
Open this publication in new window or tab >>Characterization of Conduction and Polarization Properties of HVDC Cable XLPE Insulation Materials
2018 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

High voltage direct current (HVDC) cables with extruded insulation system were introduced in 1998. Since then this technology has been growing rapidly with many installations that are today operational at voltages up to 320 kV. With fast developments during the last few years, extruded DC cable systems for operation voltages as high as 640 kV are now commercially available.

Due to the importance of DC conductivity in the distribution of electrical field across the cable insulation, a good understanding of the DC conduction physics is of key importance to the design of robust HVDC cables. Currently, crosslinked polyethylene (XLPE) is the dominating material used in the insulation system of extruded DC cables. Since XLPE includes peroxide decomposition products (PDP), understanding their role on conduction behavior of the insulation system has been of great interest. The PDP and other chemical species can move in the system through diffusion which makes the characterization of cable insulation more challenging. Besides, like other semi-crystalline polymers, morphology of the XLPE evolves with temperature and over time. These changes in the material pose challenges to their electrical characterization by requiring stringent control of parameters during preparation, storage and measurement.

In this work, different electrical characterization techniques relevant to polymeric insulation materials are discussed highlighting their applications and limitations. A set of considerations during preparation, storage and measurement of polymeric samples is listed and implemented in the studies. The design and performance of a high voltage DC conductivity measurement setup is evaluated.

Thick low density polyethylene (LDPE) and XLPE press molded plaque samples together with plaque samples extracted from cable insulation are prepared and studied using the high voltage DC conductivity measurement setup. Conductivity measurements are done both under static and dynamic temperature programs. Different preparations and test programs are used and the results are analyzed and compared.

Investigations show that the type of protective press film used during press molding of samples can strongly influence the results and using polyethylene terephthalate (PET) film appears to lead to the higher measured conductivity levels. Studies with dynamic temperature program reveal a non-monotonic temperature dependence of apparent DC conductivity of samples with certain

preparation which to the author’s best of knowledge has not been previously

reported in the literature.

Studies on XLPE and LDPE plaque samples with different heat-treatments show that the behavior of conductivity during thermal dynamics depends on the type of the press film. Upon degassing, samples pressed with PET film show a decline of conductivity at all temperatures and a reduction of the non-monotonic behavior. Based on the results from the experiments, a set of hypotheses as potential explanation of this behavior is put forward and discussed.

Abstract [sv]

Extruderade likspännings (DC) kablar infördes 1998. Sedan dess ha likspännings (DC) kabeltekniken utvecklats snabbt och har lett till många existerande kabelsysteminstallationer med driftspänningar på upp till 320 kV och typprovade extruderade DC kabelsystem har nått driftspänningar på upp till 640 kV.

Den elektriska ledningsförmågan påverkan på den elektrisk fältfördelning i isolationsmaterial vid DC, kräver en god förståelse av hur den elektriska konduktiviteten påverkas av fältstyrka, temperatur och en mängd materialparametrar relaterade till polymerernas morfologi och kemi. Idag är tvärbunden polyeten (PEX) det dominerande material som används i isolationssystem för extruderade DC-kablar. PEX innehåller tvärbindningsrestgaser och det har lett till stort intresse för bättre förståelse av tvärbindningsrestgasers påverkan på materialets elektriska egenskaper. Restgaserna och andra kemikalier är flyktiga och kan röra sig i systemet genom diffusion som gör karakterisering av kabelisoleringen mer utmanande. Dessutom, liksom andra semi-kristallina polymerer, ändras PEX materialets morfologi med temperatur över tiden. Med tanke på att materialet kan ändras under provpreparering, lagring och även vid mätning, så måste samtliga steg ovan väljas mycket försiktigt.

I detta arbete, diskuteras olika karakteriserings tekniker för polymera isolationsmaterial och deras möjligheter och begränsningar. Viktiga aspekter för provpreparering, lagring och mätning är listade till vilka tagits hänsyn till under detta arbete. Design och prestanda av mätuppställningen för DC ledningsförmåga har utvärderats.

Tjocka plattprover av pressad LDPE och PEX samt plattor ursvarvade från kommersiellt tillverkade högspänningskablar preparerades och studier genomfördes på deras ledningsförmåga under högspänning DC. Mätning av ledningsförmåga genomfördes både med konstant och med varierande temperatur enligt specifika program. Olika provprepareringar och provprogrammen användes och resultaten analyserades och jämfördes.

Resultaten visar att typ av pressfilm som använts under provpreparering kan ha en stor betydelse för resultaten och användning av PET filmer leder till högsta ledningsförmåga. Studier med varierande temperatur program hos PEX och LDPE

plattor med visa prepareringar, visar ett icke monotont beroende av DC ledningsförmåga på temperatur som tidigare inte rapporterats i litteraturen.

Studier på PEX och LDPE plattor med olika värmebehandling visar att beteenden beror på typ av press film som används under provpreparering. Efter avgasning, uppvisar prover pressade med PET film en minskning i ledningsförmåga i samtliga temperaturer och en minskning av det icke monotona temperatur beteendet. Baserade på experimentresultaten har ett antal hypoteser som förklaring av observationer tagit fram och diskuterats.

Place, publisher, year, edition, pages
stockholm: KTH Royal Institute of Technology, 2018. p. 89
Series
TRITA-EECS-AVL ; 2018:45
Keywords
HVDC insulation, power cable insulation, cross-linked polyethylene insulation, conductivity, dielectric losses, space charge
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electrical Engineering
Identifiers
urn:nbn:se:kth:diva-228220 (URN)978-91-7729-817-5 (ISBN)
Public defence
2018-06-08, Sal Q2, Osquldas Väg 10, Stockholm, 13:00 (English)
Opponent
Supervisors
Note

QC 20180521

Available from: 2018-05-22 Created: 2018-05-18 Last updated: 2018-05-23Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopushttps://ieeexplore.ieee.org/document/7547828/

Search in DiVA

By author/editor
Ghorbani, Hossein
By organisation
Electromagnetic Engineering
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 19 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf