Fault-Observability Enhancement in Distribution Networks Using Power Quality Monitors
KTH, School of Electrical Engineering and Computer Science (EECS).
Univ Waterloo, Elect & Comp Engn Dept, Waterloo, ON, Canada..
Khalifa Univ, Elect & Comp Engn Dept, Abu Dhabi, U Arab Emirates..
2018 (English)In: 2018 IEEE Electrical Power and Energy Conference (EPEC), Institute of Electrical and Electronics Engineers (IEEE), 2018, article id 8598287Conference paper, Published paper (Refereed)
Abstract [en]

As far as continuous supply and reliable power delivery to the distribution system customers are concerned, finding a practical and cost-effective method for locating faults after their occurrence is of high importance. In this study, a method is proposed to determine the optimal number and location of power quality monitors (PQMs) to make the distribution network fault-observable, that means, to be able to locate faults as precisely as possible. Moreover, as placement of PQMs is highly dependent on the network topology, the proposed method considers the most probable configurations of the network for optimization. The error of measuring equipment and its effect on number of PQMs is also taken into consideration. The defined objective functions of this study aim to minimize the cost of installing PQMs while minimizing the number of blind-pairs and maximizing the fault-observability level of the network. These objective functions are optimized using Multi-Objective Particle Swarm Optimization (MOPSO) technique. Additionally, to have a better economic evaluation, two scenarios are defined based on the accuracy class of monitoring equipment. The effectiveness of the proposed method is corroborated using simulation results for the IEEE 123-bus distribution test system.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE), 2018. article id 8598287
Series
IEEE Electrical Power and Energy Conference, ISSN 2381-2842
Keywords [en]
Distribution system, Fault location, fault-observability, MOPSO technique, Power quality monitor
National Category
Communication Systems
Identifiers
URN: urn:nbn:se:kth:diva-245092DOI: 10.1109/EPEC.2018.8598287ISI: 000458814200006Scopus ID: 2-s2.0-85061924355ISBN: 978-1-5386-5419-4 (print)OAI: oai:DiVA.org:kth-245092DiVA, id: diva2:1294641
Conference
IEEE Electrical Power and Energy Conference (EPEC), OCT 10-11, 2018, Toronto, CANADA
Note

QC 20190308

Available from: 2019-03-08 Created: 2019-03-08 Last updated: 2019-03-08Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Davarinejad, Ehsan
By organisation
School of Electrical Engineering and Computer Science (EECS)
Communication Systems

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 6 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf