Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
CONCEPTUAL DEVELOPMENT OF THE EARTH TUBE COOLING SYSTEM FOR A TALL BUILDING
Tianjin Univ, Sch Architecture, Rm 303,Bldg 21,92 Weijin Rd, Tianjin 300072, Peoples R China..
KTH, School of Architecture and the Built Environment (ABE), Urban Planning and Environment, Urban and Regional Studies.
Tianjin Univ, Sch Architecture, Rm 303,Bldg 21,92 Weijin Rd, Tianjin 300072, Peoples R China..
Tianjin Univ, Sch Architecture, Rm 303,Bldg 21,92 Weijin Rd, Tianjin 300072, Peoples R China..
2019 (English)In: JOURNAL OF GREEN BUILDING, Vol. 14, no 2, p. 3-28Article in journal (Refereed) Published
Abstract [en]

Earth tubes are earth-to-air heat exchangers that are frequently utilized in energy conscious low-rise buildings, but are scarcely reported for tall buildings. The feasibility of applying earth tube cooling to tall buildings in a hot summer and cold winter climate zone was studied in this paper. Firstly, the designed cooling load of a tall building was obtained from the energy simulation using the baseline and the modified models with applicable energy efficiency measures. Based on the load, the required cooling capacity, the overall section area and the effective length of the earth tube system was deduced from the heat transfer and fluid flow calculation analytically. Then the performance of the earth tube system was crosschecked and verified via the Computational Fluid Dynamics (CFD) simulation. In the CFD simulation, earth tubes with different diameters and lengths, as well as a full-scale earth tube model with surrounding soil above the depth of constant temperature, were investigated. The outlet air temperatures of the full-scale models were computed with the consideration of different axial distances between adjacent tubes. Meanwhile, multiple conceptual design schemes and the tunnel construction method for the earth tube system were proposed from the perspective of performance enhancement, constructability, efficiency and economy. It revealed that earth tube systems are conditionally feasible for some tall buildings if their design guidelines for climate, underground spaces, construction method, friction of tube interior surface, optimization of effective length and axial distance, as well as synergy with other energy efficiency measures are followed. Even the cooling capacity of earth tubes degrade with time due to the accumulated heat underground, but in a hot summer and cold winter climate zone it can still possibly produce cooled air for a tall building with a Floor Area Ratio of less than 7 effectively in summer.

Place, publisher, year, edition, pages
COLLEGE PUBLISHING , 2019. Vol. 14, no 2, p. 3-28
Keywords [en]
earth tube, energy efficiency, tall building, cooling capacity, overall section area, effective length
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:kth:diva-252659ISI: 000467601400001OAI: oai:DiVA.org:kth-252659DiVA, id: diva2:1321780
Note

QC 20190610

Available from: 2019-06-10 Created: 2019-06-10 Last updated: 2019-06-10Bibliographically approved

Open Access in DiVA

No full text in DiVA

Authority records BETA

Xu, Miao

Search in DiVA

By author/editor
Xu, Miao
By organisation
Urban and Regional Studies
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 11 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf