Contribution of travelling wave propagation time to the speed of optical link protections in multi-terminal high-voltage DC systems
KTH, School of Electrical Engineering and Computer Science (EECS), Electric Power and Energy Systems.ORCID iD: 0000-0002-1558-2539
KTH, School of Electrical Engineering and Computer Science (EECS), Electric Power and Energy Systems.ORCID iD: 0000-0002-8565-4753
2019 (English)In: IET Generation, Transmission & Distribution, ISSN 1751-8687, E-ISSN 1751-8695, Vol. 13, no 14, p. 3078-3085Article in journal (Refereed) Published
Abstract [en]

During faults in multi-terminal high-voltage DC systems, the disturbance will quickly become evident throughout the entire system. If DC breakers are included in such systems, the entire fault clearing process needs to occur within a few milliseconds. Therefore, DC line protection schemes based on telecommunication have previously been discarded by some authors as their performance is constrained by the communication delay. However, telecommunication-based detection methods offer some very favourable features, one being that selectivity can be achieved without coordination of settings. In this study, several telecommunication-based protection schemes are evaluated with regards to their minimum possible detection time when considering telecommunication delay. It is shown that they perform best during faults located at the remote end of a line, i.e. fault locations that are difficult to reliably detect using single-ended methods. Therefore, it is reasonable that the most reliable protection system will consist of both single-ended and communication-based methods because they complement each other well. Furthermore, it is shown that the travelling wave differential protection offers the shortest theoretical detection time due to the wave propagation delay being included in the formulation.

Place, publisher, year, edition, pages
Institution of Engineering and Technology, 2019. Vol. 13, no 14, p. 3078-3085
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-255739DOI: 10.1049/iet-gtd.2019.0344ISI: 000476558800019Scopus ID: 2-s2.0-85069442033OAI: oai:DiVA.org:kth-255739DiVA, id: diva2:1342336
Note

QC 20190813

Available from: 2019-08-13 Created: 2019-08-13 Last updated: 2019-08-13Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records BETA

Johannesson, NiclasNorrga, Staffan

Search in DiVA

By author/editor
Johannesson, NiclasNorrga, Staffan
By organisation
Electric Power and Energy Systems
In the same journal
IET Generation, Transmission & Distribution
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 18 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf