Mathematical Modeling and Performance Analysis of Seawater Heat Exchanger in Closed-Loop Seawater-Source Heat Pump System
Tianjin Univ, Sch Environm Sci & Technol, Tianjin 300072, Peoples R China..
Tianjin Univ, Sch Environm Sci & Technol, Tianjin 300072, Peoples R China..
Tianjin Univ, Sch Environm Sci & Technol, Tianjin 300072, Peoples R China..
Tianjin Univ, Sch Environm Sci & Technol, Tianjin 300072, Peoples R China..
Show others and affiliations
2019 (English)In: Journal of energy engineering, ISSN 0733-9402, E-ISSN 1943-7897, Vol. 145, no 4, article id 04019012Article in journal (Refereed) Published
Abstract [en]

The seawater source heat pump (SWHP) utilizes low-grade energy from seawater to satisfy heating/cooling requirements of coastal buildings. Compared with the open-loop SWHP system, the closed-loop system is more stable and reliable when used in cold regions because the seawater heat exchanger can mitigate icing and corrosion problems. This study established mathematical modeling for the seawater heat exchanger, which was validated by the experimental results, to estimate the heat transfer performance. The thermal performance of the seawater heat exchanger under different operating conditions was predicted, and the effects of several key parameters on thermal resistance were analyzed. The results revealed that the pipe wall thermal resistance of the original heat exchanger was the most important factor limiting the heat transfer. Hence, a cost analysis of the heat exchangers with different pipe materials was conducted, and the steel pipe with anticorrosive coating was proven to be optimal in reducing pipe wall thermal resistance and economy. The findings are useful in designing and optimizing the seawater heat exchanger and promoting the application of ocean thermal energy.

Place, publisher, year, edition, pages
ASCE-AMER SOC CIVIL ENGINEERS , 2019. Vol. 145, no 4, article id 04019012
Keywords [en]
Seawater heat exchanger, Heat transfer modeling, Thermal resistance, Economic analysis
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:kth:diva-255173DOI: 10.1061/(ASCE)EY.1943-7897.0000608ISI: 000471687400003Scopus ID: 2-s2.0-85065183215OAI: oai:DiVA.org:kth-255173DiVA, id: diva2:1348484
Note

QC 20190904

Available from: 2019-09-04 Created: 2019-09-04 Last updated: 2019-09-04Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records BETA

Zhang, Yang

Search in DiVA

By author/editor
Zhang, Yang
By organisation
Energy Processes
In the same journal
Journal of energy engineering
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 12 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf