kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Quantitative Glucose Measurement on a Synthetic Paper Test Strip
KTH, School of Electrical Engineering and Computer Science (EECS), Intelligent systems, Micro and Nanosystems. Shantou Univ, Dept Biomed Engn, 243 Dame Rd, Shantou 515063, Peoples R China.;KTH Royal Inst Technol, Div Micro & Nanosyst, Malvinas Vag 10, S-10044 Stockholm, Sweden..ORCID iD: 0000-0003-2444-6771
KTH, Centres, Science for Life Laboratory, SciLifeLab.ORCID iD: 0000-0001-8531-5607
KTH, School of Electrical Engineering and Computer Science (EECS), Intelligent systems, Micro and Nanosystems.ORCID iD: 0000-0001-8248-6670
2021 (English)In: 2021 IEEE 16th international conference on nano/micro engineered and molecular systems (nems), Institute of Electrical and Electronics Engineers (IEEE) , 2021, p. 1310-1313Conference paper, Published paper (Refereed)
Abstract [en]

To measure the glucose concentration in blood is an important target for point-of-care diagnostics. We integrated a colorimetric assay on synthetic paper, a novel lateral flow test substrate, for quantitative glucose measurement. At first, we dropped a colorimetric enzyme assay in silk solution on one end of the synthetic paper test strip and dried it in a vacuum chamber for overnight. After that, we flowed glucose solution on the test strip, imaged the test strip by smartphone, and analyzed the images with ImageJ. Exponential fitting of the experimental data revealed a low limit of detection of the assay to be 0.21 mM, and the R-2 is 0.99 for the concentration (0 - 15 mM), which covers the clinically relevant blood glucose concentration (2 - 12 mM). This test strip can he further developed into a test for glucose quantification in whole blood.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE) , 2021. p. 1310-1313
Series
International Conference on Nano-Micro Engineered and Molecular Systems NEMS, ISSN 2474-3747
National Category
Analytical Chemistry
Identifiers
URN: urn:nbn:se:kth:diva-303383DOI: 10.1109/NEMS51815.2021.9451494ISI: 000693407600153Scopus ID: 2-s2.0-85113308525OAI: oai:DiVA.org:kth-303383DiVA, id: diva2:1603380
Conference
16th IEEE International Conference on Nano/Micro Engineered and Molecular Systems (IEEE-NEMS), APR 25-29, 2021, Xiamen, PEOPLES R CHINA
Note

Part of proceedings: ISBN 978-0-7381-2429-2, QC 20230117

Available from: 2021-10-15 Created: 2021-10-15 Last updated: 2023-01-17Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Guo, WeijinHansson, Jonasvan der Wijngaart, Wouter

Search in DiVA

By author/editor
Guo, WeijinHansson, Jonasvan der Wijngaart, Wouter
By organisation
Micro and NanosystemsScience for Life Laboratory, SciLifeLab
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 87 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf