Thermal response tests: A biased parameter estimation procedure?
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration.ORCID iD: 0000-0002-9120-8637
KTH, School of Industrial Engineering and Management (ITM), Energy Technology.ORCID iD: 0000-0002-0550-2769
2021 (English)In: Geothermics, ISSN 0375-6505, E-ISSN 1879-3576, Vol. 97, article id 102221Article in journal (Refereed) Published
Abstract [en]

Thermal response tests are used to estimate the thermal properties of the ground and the borehole heat exchanger being tested. They are thus important for the design of borehole thermal energy storages and ground source heat pump systems. In this study, a theoretical framework is proposed in order to investigate if noise on the heat rate leads to a bias in the parameter estimation. Under the sole assumption of a linear time-invariant system and the use of the sum of squared errors as cost function, it is shown analytically that estimates are in fact biased when the heat rate is corrupted by noise. To understand how large this bias can be, a Monte-Carlo study is performed. It includes more than 126,000 simulations with different noises, thermal parameters and heat rate profiles. Negative biases as high as -0.44 W/(m K) (11%) and -11.10(-3) m K/W (4.1%) are observed for the thermal conductivity and borehole thermal resistance estimates, respectively. In addition, the parameter estimation is stochastic due to randomness of measurement noises. This cannot be ignored since only one thermal response test is performed, in general. Population of estimates with 95% confidence intervals as large as 1.0 W/(m K) (25%) and 24.10(-3) m K/W (9.4%) appear in this study. Although the bias and confidence intervals are not significant in all simulated cases, they cannot be generally disregarded and one should therefore be mindful of this potential issue when analyzing thermal response tests. An observed trend is that the confidence intervals and bias are higher for higher parameter values, with a particular dependency on thermal conductivity. To reduce the bias and spread of the estimates, having larger heat rate per meter appears to be a good strategy. Having a higher sampling frequency and/or longer tests might also help, but only in reducing the spread of the estimates, not the bias.

Place, publisher, year, edition, pages
Elsevier BV , 2021. Vol. 97, article id 102221
Keywords [en]
Thermal response test, Parameter estimation, Error-in-variables, Bias, BTES, Monte-Carlo, LTI
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:kth:diva-304181DOI: 10.1016/j.geothermics.2021.102221ISI: 000706996700001Scopus ID: 2-s2.0-85115939772OAI: oai:DiVA.org:kth-304181DiVA, id: diva2:1609038
Note

QC 20211105

Available from: 2021-11-05 Created: 2021-11-05 Last updated: 2022-06-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Mazzotti Pallard, WillemLazzarotto, Alberto

Search in DiVA

By author/editor
Mazzotti Pallard, WillemLazzarotto, Alberto
By organisation
Applied Thermodynamics and RefrigerationEnergy Technology
In the same journal
Geothermics
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 158 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf