kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Image Quality And Potential Dose Reduction Using Advanced Modeled Iterative Reconstruction (ADMIRE) In Abdominal Ct - A Review
Linköping Univ, Dept Radiol, Linköping, Sweden.;Linköping Univ, Dept Hlth Med & Caring Sci, Linköping, Sweden.;Linköping Univ, Ctr Med Image Sci & Visualizat CMIV, Linköping, Sweden..
Linköping Univ, Dept Hlth Med & Caring Sci, Linköping, Sweden.;Linköping Univ, Dept Med Phys, Linköping, Sweden..
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Biomedical Engineering and Health Systems, Medical Imaging.ORCID iD: 0000-0002-7750-1917
Linköping Univ, Dept Radiol, Linköping, Sweden.;Linköping Univ, Dept Hlth Med & Caring Sci, Linköping, Sweden.;Linköping Univ, Ctr Med Image Sci & Visualizat CMIV, Linköping, Sweden..
Show others and affiliations
2021 (English)In: Radiation Protection Dosimetry, ISSN 0144-8420, E-ISSN 1742-3406, Vol. 195, no 3-4, p. 177-187Article, review/survey (Refereed) Published
Abstract [en]

Traditional filtered back projection (FBP) reconstruction methods have served the computed tomography (CT) community well for over 40 years. With the increased use of CT during the last decades, efforts to minimise patient exposure, while maintaining sufficient or improved image quality, have led to the development of model-based iterative reconstruction (MBIR) algorithms from several vendors. The usefulness of the advanced modeled iterative reconstruction (ADMIRE) (Siemens Healthineers) MBIR in abdominal CT is reviewed and its noise suppression and/or dose reduction possibilities explored. Quantitative and qualitative methods with phantom and human subjects were used. Assessment of the quality of phantom images will not always correlate positively with those of patient images, particularly at the higher strength of the ADMIRE algorithm. With few exceptions, ADMIRE Strength 3 typically allows for substantial noise reduction compared to FBP and hence to significant (approximate to 30%) patient dose reductions. The size of the dose reductions depends on the diagnostic task.

Place, publisher, year, edition, pages
Oxford University Press (OUP) , 2021. Vol. 195, no 3-4, p. 177-187
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:kth:diva-305125DOI: 10.1093/rpd/ncab020ISI: 000711245400009PubMedID: 33778892Scopus ID: 2-s2.0-85118598045OAI: oai:DiVA.org:kth-305125DiVA, id: diva2:1613235
Note

QC 20211122

Available from: 2021-11-22 Created: 2021-11-22 Last updated: 2022-06-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Smedby, Örjan

Search in DiVA

By author/editor
Smedby, Örjan
By organisation
Medical Imaging
In the same journal
Radiation Protection Dosimetry
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 58 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf