Experimental investigation of the heat transfer from the helical coil heat exchanger using bubble injection for cold thermal energy storage system
KN Toosi Univ Technol, Dept Mech Engn, Tehran, Iran..
KN Toosi Univ Technol, Dept Mech Engn, Tehran, Iran.;Chalmers Univ Technol, Div Energy Technol, Gothenburg, Sweden..
KN Toosi Univ Technol, Dept Mech Engn, Tehran, Iran..
KTH, School of Engineering Sciences (SCI), Centres, Linné Flow Center, FLOW. KTH, School of Engineering Sciences (SCI), Engineering Mechanics, Fluid Mechanics and Engineering Acoustics.ORCID iD: 0000-0002-1663-3553
2022 (English)In: Applied Thermal Engineering, ISSN 1359-4311, E-ISSN 1873-5606, Vol. 200, article id 117559Article in journal (Refereed) Published
Abstract [en]

This study investigates cold thermal energy storage (CTES) using a helical coil heat exchanger modified with bubble injection. One of the effective methods for increasing the heat transfer rate in heat exchangers is using bubble injection. A helical coil heat exchanger is immersed inside a cylindrical water storage tank, where the helical coil is the evaporator of a vapor compression refrigeration cycle (VCRC) and provides the designed cooling. Experimental studies were carried out to examine the impact of bubble injection on Nusselt number, the temperature differences in the storage tank, exergy degradation in the evaporator, and cycle coefficient of performance (COP). The bubbles were injected from the bottom of the storage tank in four different geometries at airflow rates ranging from 3 to 11 L/min. The experimental results of this study revealed that bubble injection could significantly increase the COP and heat transfer rate from the storage tank, as well as the exergy destruction and Nusselt number (Nu). This increase was highly dependent on the geometry and flow rate of the bubble injection. The results also indicated that the bubble injection has an optimal flow rate value, which was 9 L/min in this study. More specifically, the COP of the refrigeration cycle and the Nu number increased by 124% and 452%, respectively, compared to the non-bubble injection mode. Finally, for calculating the outside Nusselt number of the helical coil, an empirical correlation as a function of bubble flow rate and bubble injection angle was proposed.

Place, publisher, year, edition, pages
Elsevier BV , 2022. Vol. 200, article id 117559
Keywords [en]
Energy storages, Helical coils, Air bubble injection, Nusselt number, COP improvement
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:kth:diva-305614DOI: 10.1016/j.applthermaleng.2021.117559ISI: 000712101800001Scopus ID: 2-s2.0-85116908019OAI: oai:DiVA.org:kth-305614DiVA, id: diva2:1617157
Note

QC 20211206

Available from: 2021-12-06 Created: 2021-12-06 Last updated: 2022-06-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Örlü, Ramis

Search in DiVA

By author/editor
Örlü, Ramis
By organisation
Linné Flow Center, FLOWFluid Mechanics and Engineering Acoustics
In the same journal
Applied Thermal Engineering
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 180 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf