Optimal controlled islanding considering frequency-arresting and frequency-stabilising constraints: A graph theory-assisted approach
KTH, School of Electrical Engineering and Computer Science (EECS), Electrical Engineering, Electric Power and Energy Systems.ORCID iD: 0000-0002-9998-9773
2021 (English)In: IET Generation, Transmission & Distribution, ISSN 1751-8687, E-ISSN 1751-8695, Vol. 15, no 14, p. 2044-2060Article in journal (Refereed) Published
Abstract [en]

The optimal controlled islanding of power systems is a practical solution to prevent system blackouts if the boundary of islands and corrective control actions in each island are carefully specified. This paper establishes a model for the controlled islanding problem by a proposed mixed integer linear program (MILP). The frequency-arresting (FA) and frequency-stabilising (FS) constraints are linearised and incorporated in our FA-FS-constrained MILP model to prevent triggering of load shedding (LS) relays. This achievement makes our model capable of handling low-inertia networks. Intentional LS and stepwise generation curtailment are corrective actions accommodated for frequency control and power mismatch considerations. These corrective actions increase the degree of freedom and broaden the feasible space of the MILP model under the envisaged tough operating conditions. Our model's computational efficiency is improved using a proposed graph theory-based network reduction technique. The basic groups of coherent generators, determined in the offline mode, are aggregated as equivalent buses using an extended Steiner tree method. A graph-path determination technique is also proposed to generate disconnection constraints (between equivalent buses of incoherent areas) and bus-allocation constraints. Simulation results on the IEEE 39-bus test system and a 76-bus case study verify the proposed network reduction technique's effectiveness and the MILP model.

Place, publisher, year, edition, pages
Institution of Engineering and Technology (IET) , 2021. Vol. 15, no 14, p. 2044-2060
Keywords [en]
Buses, Computation theory, Computational efficiency, Degrees of freedom (mechanics), Distributed power generation, Electric load shedding, Integer programming, Power control, Coherent generators, Controlled islanding, Corrective actions, Corrective control actions, Mixed integer linear program, Network reduction, Operating condition, Practical solutions, Graph theory
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-307076DOI: 10.1049/gtd2.12154ISI: 000626524500001Scopus ID: 2-s2.0-85102171622OAI: oai:DiVA.org:kth-307076DiVA, id: diva2:1631011
Note

QC 20220121

Available from: 2022-01-21 Created: 2022-01-21 Last updated: 2022-06-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Hesamzadeh, Mohammad Reza

Search in DiVA

By author/editor
Hesamzadeh, Mohammad Reza
By organisation
Electric Power and Energy Systems
In the same journal
IET Generation, Transmission & Distribution
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 6 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf