kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Vertical ionization potential benchmark for unitary coupled-cluster and algebraic-diagrammatic construction methods
Heidelberg Univ, Interdisciplinary Ctr Sci Comp, Neuenheimer Feld 205, D-69120 Heidelberg, Germany..
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Theoretical Chemistry and Biology. Heidelberg Univ, Interdisciplinary Ctr Sci Comp, Neuenheimer Feld 205, D-69120 Heidelberg, Germany..ORCID iD: 0000-0003-4219-0036
Heidelberg Univ, Interdisciplinary Ctr Sci Comp, Neuenheimer Feld 205, D-69120 Heidelberg, Germany..
2022 (English)In: Journal of Chemical Physics, ISSN 0021-9606, E-ISSN 1089-7690, Vol. 156, no 5, p. 054114-, article id 054114Article in journal (Refereed) Published
Abstract [en]

The performance of several methods for the calculation of vertical ionization potentials (IPs) or, more generally, electron-detachment energies based on unitary coupled-cluster (UCC) theory and the algebraic-diagrammatic construction (ADC) scheme is evaluated with respect to benchmark data computed at the level of equation-of-motion coupled-cluster theory, including single, double, and triple excitations (IP-EOM-CCSDT). Based on a statistical evaluation of about 200 electron-detached states of 41 molecules, the second-order methods IP-ADC(2) and IP-UCC2 show modest accuracies with IP-EOM-CCSDT as reference, exposing a mean signed error and a standard deviation of the error of -0.54 & PLUSMN; 0.50 and -0.49 & PLUSMN; 0.54 eV, respectively, accompanied by a mean absolute error (MAE) of 0.61 and 0.58 eV, respectively. The strict third-order IP-ADC method demonstrates an accuracy of 0.26 & PLUSMN; 0.35 eV (MAE = 0.35 eV), while the IP-UCC3 method is slightly more accurate with 0.24 & PLUSMN; 0.26 eV (MAE = 0.29 eV). Employing the static self-energy computed using the Dyson expansion method (DEM) improves the IP-ADC(3) performance to 0.27 & PLUSMN; 0.28 eV, with the mean absolute error of this method being 0.32 eV. However, employing the simpler improved fourth-order scheme sigma(4+) for the static self-energy provides almost identical results as the DEM. Based on the quality of the present benchmark results, it therefore appears not necessary to use the computationally more demanding DEM.

Place, publisher, year, edition, pages
AIP Publishing , 2022. Vol. 156, no 5, p. 054114-, article id 054114
National Category
Theoretical Chemistry
Identifiers
URN: urn:nbn:se:kth:diva-309561DOI: 10.1063/5.0079047ISI: 000752977700001PubMedID: 35135273Scopus ID: 2-s2.0-85124270926OAI: oai:DiVA.org:kth-309561DiVA, id: diva2:1642641
Note

QC 20220307

Available from: 2022-03-07 Created: 2022-03-07 Last updated: 2022-06-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Hodecker, Manuel

Search in DiVA

By author/editor
Hodecker, Manuel
By organisation
Theoretical Chemistry and Biology
In the same journal
Journal of Chemical Physics
Theoretical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 41 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf